Literature DB >> 21068019

X-ray tube current modulation and patient doses in chest CT.

Wenjun He1, Walter Huda, Dennise Magill, Emily Tavrides, Hai Yao.   

Abstract

The aim of the study was to investigate how patient effective doses vary as a function of X-ray tube projection angle, as well as the patient long axis, and quantify how X-ray tube current modulation affects patient doses in chest CT examinations. Chest examinations were simulated for a gantry CT scanner geometry with projections acquired for a beam width of 4 cm. PCXMC 2.0.1 was used to calculate patient effective doses at 15° intervals around the patient's isocentre, and at nine locations along the patient long axis. Idealised tube current modulation schemes were modelled as a function of the X-ray tube angle and the patient long axis. Tube current modulations were characterised by the modulation amplitude R, which was allowed to vary between 1.5 and 5. Effective dose maxima occur for anteroposterior projections at the location of the (radiosensitive) breasts. The maximum to minimum ratio of effective doses as a function of the patient long axis was 4.9, and as a function of the X-ray tube angle was 2.1. Doubling the value of R reduces effective doses from longitudinal modulation alone by ∼4% and from angular modulation alone by ∼2%. In chest CT, tube current modulation schemes currently have longitudinal R values of ∼2.2, and angular R values that range between 1.5 and 3.4. Current X-ray tube current modulation schemes are expected to reduce patient effective doses in chest CT examinations by ∼10%, with longitudinal modulation accounting for two-thirds and angular modulation for the remaining one-third.

Entities:  

Mesh:

Year:  2010        PMID: 21068019     DOI: 10.1093/rpd/ncq291

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  4 in total

1.  A comparison of methods to estimate organ doses in CT when utilizing approximations to the tube current modulation function.

Authors:  Maryam Khatonabadi; Di Zhang; Kelsey Mathieu; Hyun J Kim; Peiyun Lu; Dianna Cody; John J Demarco; Chris H Cagnon; Michael F McNitt-Gray
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.071

2.  Estimating lung, breast, and effective dose from low-dose lung cancer screening CT exams with tube current modulation across a range of patient sizes.

Authors:  Anthony J Hardy; Maryam Bostani; Kyle McMillan; Maria Zankl; Cynthia McCollough; Chris Cagnon; Michael McNitt-Gray
Journal:  Med Phys       Date:  2018-09-24       Impact factor: 4.071

3.  Estimating organ doses from tube current modulated CT examinations using a generalized linear model.

Authors:  Maryam Bostani; Kyle McMillan; Peiyun Lu; Grace Hyun J Kim; Dianna Cody; Gary Arbique; S Bruce Greenberg; John J DeMarco; Chris H Cagnon; Michael F McNitt-Gray
Journal:  Med Phys       Date:  2017-04       Impact factor: 4.071

4.  The feasibility of a regional CTDIvol to estimate organ dose from tube current modulated CT exams.

Authors:  Maryam Khatonabadi; Hyun J Kim; Peiyun Lu; Kyle L McMillan; Chris H Cagnon; John J DeMarco; Michael F McNitt-Gray
Journal:  Med Phys       Date:  2013-05       Impact factor: 4.071

  4 in total