Literature DB >> 21062964

Effect of mini-implant length and diameter on primary stability under loading with two force levels.

Athina Chatzigianni1, Ludger Keilig, Susanne Reimann, Theodore Eliades, Christoph Bourauel.   

Abstract

Mini-implants are widely utilized as anchorage units in orthodontic treatment. Nevertheless, there are factors that interfere with their clinical performance. The aim of this study was to examine the impact of length and diameter on the primary stability of two different types of orthodontic mini-implants loaded with two force levels. A total of 90 self-drilling mini-implants were inserted in bovine ribs in vitro, 62 of which were used in data analysis. The mini-implants were of two types, Aarhus (n=29) and Lomas (n=33), of two lengths (7 and 9 mm, n=26 and n=28, respectively), and of two diameters (1.5 and 2 mm, Lomas only, n=6 and n=8, respectively). A closed nickel-titanium (NiTi) coil spring was attached to each mini-implant. Half of the preparations were loaded with a low force of 0.5 N and the other half with a force of 2.5 N. Mini-implant deflections during force application were non-invasively registered using a three-dimensional (3D) laser-optical system. The results were analysed with analysis of variance for the effects of implant type, implant length, and force level, and with a t-test for the study of the effect of diameter in two different diameter variants of the same (Lomas) implant. In the low-force group, implant displacements were not statistically significant difference according to the investigated parameters. In the high-force group, the 9 mm long mini-implants displaced significantly less (10.5±7.5 μm) than the 7 mm long (22.3±11.3 μm, P<0.01) and the 2 mm wide significantly less (8.8±2.2 μm) than the 1.5 mm implants (21.9±1.5 μm, P<0.001). The force level at which significance occurred was 1 N. The rotation of the Lomas mini-implants in the form of tipping was significantly higher than that of the Aarhus mini-implants at all force levels. Implant length and diameter become statistically significant influencing parameters on implant stability only when a high force level is applied.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21062964     DOI: 10.1093/ejo/cjq088

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  7 in total

1.  Direct versus indirect loading of orthodontic miniscrew implants-an FEM analysis.

Authors:  C Holberg; P Winterhalder; N Holberg; I Rudzki-Janson; A Wichelhaus
Journal:  Clin Oral Investig       Date:  2012-10-31       Impact factor: 3.573

2.  Orthodontic mini-implant stability at different insertion depths : Sensitivity of three stability measurement methods.

Authors:  Manuel Nienkemper; Natascha Santel; Ralf Hönscheid; Dieter Drescher
Journal:  J Orofac Orthop       Date:  2016-06-07       Impact factor: 1.938

3.  Impact of mini-implant length on stability at the initial healing period: a controlled clinical study.

Authors:  Manuel Nienkemper; Benedict Wilmes; Alexander Pauls; Dieter Drescher
Journal:  Head Face Med       Date:  2013-10-20       Impact factor: 2.151

4.  Stress distribution patterns at mini-implant site during retraction and intrusion--a three-dimensional finite element study.

Authors:  Gautham Sivamurthy; Shantha Sundari
Journal:  Prog Orthod       Date:  2016-01-18       Impact factor: 2.750

5.  Investigation of the optimal design of orthodontic mini-implants based on the primary stability: A finite element analysis.

Authors:  Amir Hooman Sadr Haghighi; Vahid Pouyafar; Ali Navid; Mahsa Eskandarinezhad; Tannaz Abdollahzadeh Baghaei
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2019-08-14

6.  In-vitro evaluation of the effects of insertion and sterilization procedures on the mechanical and surface characteristics of mini screws.

Authors:  Civan Aved Hergel; Yasemin Bahar Acar; Mustafa Ates; Nazan Kucukkeles
Journal:  Eur Oral Res       Date:  2019-01-01

Review 7.  A Mini-review on the Effect of Mini-implants on Contemporary Orthodontic Science.

Authors:  Saeid Nosouhian; Mansour Rismanchian; Roya Sabzian; Elham Shadmehr; Hamid Badrian; Amin Davoudi
Journal:  J Int Oral Health       Date:  2015