Literature DB >> 21058238

High resolution ultrasound and magnetic resonance imaging of the optic nerve and the optic nerve sheath: anatomic correlation and clinical importance.

M Steinborn1, J Fiegler, V Kraus, C Denne, A Hapfelmeier, L Wurzinger, H Hahn.   

Abstract

PURPOSE: We performed a cadaver study to evaluate the accuracy of measurements of the optic nerve and the optic nerve sheath for high resolution US (HRUS) and magnetic resonance imaging (MRI).
MATERIALS AND METHODS: Five Thiel-fixated cadaver specimens of the optic nerve were examined with HRUS and MRI. Measurements of the optic nerve and the ONSD were performed before and after the filling of the optic nerve sheath with saline solution. Statistical analysis included the calculation of the agreement of measurements and the evaluation of the intraobserver and interobserver variation.
RESULTS: Overall a good correlation of measurement values between HRUS and MRI can be found (mean difference: 0.02-0.97 mm). The repeatability coefficient (RC) and concordance correlation coefficient (CCC) values were good to excellent for most acquisitions (RC 0.2-1.11 mm; CCC 0.684-0.949). The highest variation of measurement values was found for transbulbar sonography (RC 0.58-1.83 mm; CCC 0.615/0.608).
CONCLUSION: If decisive anatomic structures are clearly depicted and the measuring points are set correctly, there is a good correlation between HRUS and MRI measurements of the optic nerve and the ONSD even on transbulbar sonography. As most of the standard and cut-off values that have been published for ultrasound are significantly lower than the results obtained with MRI, a reevaluation of sonographic ONSD measurement with correlation to MRI is necessary. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Year:  2010        PMID: 21058238     DOI: 10.1055/s-0029-1245822

Source DB:  PubMed          Journal:  Ultraschall Med        ISSN: 0172-4614            Impact factor:   6.548


  16 in total

1.  High resolution transbulbar sonography in children with suspicion of increased intracranial pressure.

Authors:  Marc Steinborn; Melanie Friedmann; Christine Makowski; Helmut Hahn; Alexander Hapfelmeier; Hendrik Juenger
Journal:  Childs Nerv Syst       Date:  2016-01-13       Impact factor: 1.475

2.  The relationship between transorbital ultrasound measurement of the optic nerve sheath diameter (ONSD) and invasively measured ICP in children. : Part II: age-related ONSD cut-off values and patency of the anterior fontanelle.

Authors:  Llewellyn C Padayachy; Vaishali Padayachy; Ushma Galal; Travis Pollock; A Graham Fieggen
Journal:  Childs Nerv Syst       Date:  2016-09-20       Impact factor: 1.475

3.  Disambiguating the optic nerve from the surrounding cerebrospinal fluid: Application to MS-related atrophy.

Authors:  Robert L Harrigan; Andrew J Plassard; Frederick W Bryan; Gabriela Caires; Louise A Mawn; Lindsey M Dethrage; Siddharama Pawate; Robert L Galloway; Seth A Smith; Bennett A Landman
Journal:  Magn Reson Med       Date:  2015-03-07       Impact factor: 4.668

Review 4.  Non-invasive detection of intracranial pressure related to the optic nerve.

Authors:  Jian Li; Chao Wan
Journal:  Quant Imaging Med Surg       Date:  2021-06

5.  Optic nerve sheath diameter on MR imaging: establishment of norms and comparison of pediatric patients with idiopathic intracranial hypertension with healthy controls.

Authors:  B Shofty; L Ben-Sira; S Constantini; S Freedman; A Kesler
Journal:  AJNR Am J Neuroradiol       Date:  2011-11-24       Impact factor: 3.825

6.  Optic Nerve Measurement on MRI in the Pediatric Population: Normative Values and Correlations.

Authors:  C E Al-Haddad; M G Sebaaly; R N Tutunji; C J Mehanna; S R Saaybi; A M Khamis; R G Hourani
Journal:  AJNR Am J Neuroradiol       Date:  2017-12-07       Impact factor: 3.825

7.  Constructing a statistical atlas of the radii of the optic nerve and cerebrospinal fluid sheath in young healthy adults.

Authors:  Robert L Harrigan; Andrew J Plassard; Louise A Mawn; Robert L Galloway; Seth A Smith; Bennett A Landman
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-03-20

8.  The relationship between transorbital ultrasound measurement of the optic nerve sheath diameter (ONSD) and invasively measured ICP in children : Part I: repeatability, observer variability and general analysis.

Authors:  Llewellyn C Padayachy; Vaishali Padayachy; Ushma Galal; Rebecca Gray; A Graham Fieggen
Journal:  Childs Nerv Syst       Date:  2016-09-20       Impact factor: 1.475

Review 9.  Neuromuscular ultrasound of cranial nerves.

Authors:  Eman A Tawfik; Francis O Walker; Michael S Cartwright
Journal:  J Clin Neurol       Date:  2015-04       Impact factor: 3.077

10.  Correlation of measurement of optic nerve sheath diameter using ultrasound with magnetic resonance imaging.

Authors:  Chetan G Shirodkar; Kartik Munta; S Manimala Rao; M Uma Mahesh
Journal:  Indian J Crit Care Med       Date:  2015-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.