Reliability and the smallest detectable differences of lateral cephalometric measurements.

Janalt Damstra1, James J R Huddleston Slater, Zacharias Fourie, Yijin Ren.   

Abstract

INTRODUCTION: The aim of this study was to determine the reliability and the measuring error (by means of the smallest detectable error) of 11 angular and 4 linear measurements commonly used for cephalometric analysis.
METHODS: Twenty-five digital lateral cephalograms were randomly selected and traced with Viewbox software (version 3.1.1.13, dHAL Software, Kifissia, Greece). This was repeated 3 times by 2 observers during 3 sessions. There was at least 1 week between each session. Differences were analyzed with a repeated measurement analysis of variance (ANOVA). Intraobserver and interobserver reliabilities were calculated with intraclass correlation coefficients (ICC) based on absolute agreement. Measurement error was determined by means of the smallest detectable difference.
RESULTS: The intraobserver agreement of the measurements was good (ICC >0.82). SNA, SNB, ANB, and ANS-Me had the smallest intraobserver errors for both observers (>1.86 mm or degrees). Except for SN-FH (ICC = 0.76), interobserver agreement was good (ICC >0.87).
CONCLUSIONS: Determining the appropriate measuring error of cephalometric measurements by means of the smallest detectable difference is necessary to find the true difference between the start and the end of active treatment. Depending on the magnitude of clinical significance, the measuring error was possibly clinically significant for all variables tested and, therefore, questions the use of these variables to detect the true treatment effect.
Copyright © 2010 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 21055590     DOI: 10.1016/j.ajodo.2010.05.013

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  6 in total

1.  Effects of head positioning on cephalometric measurements.

Authors:  M Berneburg; B Koos; R Kratochwil; A Godt
Journal:  J Orofac Orthop       Date:  2012-10-26       Impact factor: 1.938

2.  Evaluation of the influence of patient positioning on the reliability of lateral cephalometry.

Authors:  Ovidiu-Tiberiu David; Robert-Angelo Tuce; Oana Munteanu; Adrian Neagu; Irinel Panainte
Journal:  Radiol Med       Date:  2017-03-07       Impact factor: 3.469

3.  Morphology, incidence of bridging, and dimensions of sella turcica in different racial groups.

Authors:  Fenik Kaml Muhammed; Adil O Abdullah; Zhwan Jamal Rashid; Tamara Pusic; Mohammed F Shbair; Yi Liu
Journal:  Oral Radiol       Date:  2018-04-02       Impact factor: 1.852

4.  The bridging and normal dimensions of sella turcica in Yemeni individuals.

Authors:  Rana A A M Al-Mohana; Fenik Kaml Muhammed; Xiaoguang Li; Grace Paka Lubamba
Journal:  Oral Radiol       Date:  2021-06-18       Impact factor: 1.852

5.  Tridimensional finite element analysis of teeth movement induced by different headgear forces.

Authors:  Ivan Toshio Maruo; Hiroshi Maruo; Armando Yukio Saga; Dauro Douglas de Oliveira; Marco André Argenta; Orlando Motohiro Tanaka
Journal:  Prog Orthod       Date:  2016-06-06       Impact factor: 2.750

6.  A Cephalometric Evaluation of Sexual Dimorphism of the Angle Sella-Nasion-Frankfort Horizontal Plane in Different Sagittal Classes of Malocclusion in South Indian Population.

Authors:  Sivareddy Rohit Reddy; Singaraju Gowri Sankar; Prasad Mandava; Vivek Reddy Ganugapanta; Surendra Gangavarapu; Swaroop Doddavarapu
Journal:  J Int Soc Prev Community Dent       Date:  2019-04-12
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.