Trace metal analysis following locked volar plating for unstable fractures of the distal radius.

Lucas S Rylander1, Joseph C Milbrandt, Evan Armington, Marty Wilson, David J Olysav.   

Abstract

An increase in the utilization of metallic devices for orthopaedic interventions from joint replacement to fracture fixation has raised concern over local metal ion release and possible systemic sequelae due to dissemination of these ions. Our purpose was to determine whether serum titanium concentrations were elevated in patients who had previously received a locked volar distal radius plate. Our hypothesis was that the simple presence of titanium alone in a relatively fixed implant was not enough to raise serum titanium levels. Twenty-two potential subjects who had received a volar locked distal radius plate were identified through review of a single surgeon's operative logs. Eleven met inclusion criteria. Serum titanium levels were measured in these subjects and compared to both current and historical control groups. We found no difference between controls and our study group with the exception of one control subject who is employed as a welder. This is in contrast to previous studies from our institution which found increases in titanium levels in hip and spine implants. We conclude that a locking titanium volar distal radius plate does not raise serum titanium levels in this population.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21045978      PMCID: PMC2958277     

Source DB:  PubMed          Journal:  Iowa Orthop J        ISSN: 1541-5457


  16 in total

1.  Cancer incidence in Finnish hip replacement patients from 1980 to 1995: a nationwide cohort study involving 31,651 patients.

Authors:  P Paavolainen; E Pukkala; P Pulkkinen; T Visuri
Journal:  J Arthroplasty       Date:  1999-04       Impact factor: 4.757

2.  Wear debris from hip or knee replacements causes chromosomal damage in human cells in tissue culture.

Authors:  B Daley; A T Doherty; B Fairman; C P Case
Journal:  J Bone Joint Surg Br       Date:  2004-05

3.  Metal-specific differences in levels of DNA damage caused by synovial fluid recovered at revision arthroplasty.

Authors:  A P Davies; A Sood; A C Lewis; R Newson; I D Learmonth; C P Case
Journal:  J Bone Joint Surg Br       Date:  2005-10

4.  Carcinogenic properties of wear particles from prostheses made in cobalt-chromium alloy.

Authors:  J C Heath; M A Freeman; S A Swanson
Journal:  Lancet       Date:  1971-03-20       Impact factor: 79.321

Review 5.  Metal sensitivity in patients with orthopaedic implants.

Authors:  N Hallab; K Merritt; J J Jacobs
Journal:  J Bone Joint Surg Am       Date:  2001-03       Impact factor: 5.284

6.  Nationwide study of cancer risk among hip replacement patients in Sweden.

Authors:  L B Signorello; W Ye; J P Fryzek; L Lipworth; J F Fraumeni; W J Blot; J K McLaughlin; O Nyrén
Journal:  J Natl Cancer Inst       Date:  2001-09-19       Impact factor: 13.506

7.  A study on the effects of particulate metals of orthopaedic interest on murine macrophages in vitro.

Authors:  T Rae
Journal:  J Bone Joint Surg Br       Date:  1975-11

8.  Widespread dissemination of metal debris from implants.

Authors:  C P Case; V G Langkamer; C James; M R Palmer; A J Kemp; P F Heap; L Solomon
Journal:  J Bone Joint Surg Br       Date:  1994-09

9.  Metal release in patients who have had a primary total hip arthroplasty. A prospective, controlled, longitudinal study.

Authors:  J J Jacobs; A K Skipor; L M Patterson; N J Hallab; W G Paprosky; J Black; J O Galante
Journal:  J Bone Joint Surg Am       Date:  1998-10       Impact factor: 5.284

10.  Metal-on-metal bearing surfaces.

Authors:  Joshua J Jacobs; Robert M Urban; Nadim J Hallab; Anastasia K Skipor; Alfons Fischer; Markus A Wimmer
Journal:  J Am Acad Orthop Surg       Date:  2009-02       Impact factor: 3.020

View more
  1 in total

1.  Systemic contact dermatitis due to corrosion of titanium-coated nickel and cobalt bone plate fixation: A case report.

Authors:  Oki Suwarsa; Rachel Marsella Rahardjo; Endang Sutedja; Hartati Purbo Dharmadji; Reti Hindritiani; Hendra Gunawan
Journal:  Medicine (Baltimore)       Date:  2017-12       Impact factor: 1.817