Literature DB >> 21044168

A novel in vitro approach to assess the fit of implant frameworks.

Jaafar Abduo1, Vincent Bennani, Karl Lyons, Neil Waddell, Michael Swain.   

Abstract

OBJECTIVE: To introduce a new strain gauge approach to assess the fit of fixed implant frameworks.
MATERIALS AND METHODS: A partially edentulous epoxy resin mandible model received two Straumann implants in the area of the lower left second premolar and second molar. The model was used to fabricate four zirconia and four identical cobalt-chromium alloy frameworks using a laboratory computer-aided design/computer-aided manufacturing (CAD/CAM) system. A total of four linear strain gauges were then bonded around each implant on the peri-implant structure (mesial, distal, buccal, and lingual). The experimental part was composed of two phases: qualitative and quantitative. For the qualitative assessment, the model was verified by recording the response of each strain gauge while applying a near-constant force of known directions on each implant. For the quantitative phase, the frameworks were attached on the implants and the screws were torqued to 15 N cm.
RESULTS: In the qualitative phase, the strain gauge response to every force direction was recorded. After attaching the frameworks, all frameworks produced measurable strains, but with different strain patterns. Upon correlating the two phases, the zirconia frameworks were found to be slightly smaller than the inter-implant distance, whereas the cobalt-chromium alloy frameworks tended to be slightly larger than the inter-implant distance.
CONCLUSIONS: The proposed technique is not only valid for detecting implant framework misfit but also for determining the form of inaccuracies. Model verification is an essential informative step to aid the interpretation of the pattern of framework distortion.
© 2010 John Wiley & Sons A/S.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21044168     DOI: 10.1111/j.1600-0501.2010.02019.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  3 in total

1.  A technique for in vitro fit assessment of multi-unit screw-retained implant restorations: Application of a triple-scan protocol.

Authors:  Stefan Holst; Matthias Karl; Manfred Wichmann; Ragai E Matta
Journal:  J Dent Biomech       Date:  2012-07-20

2.  Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures.

Authors:  Valdey Suedam; Rafael Tobias Moretti Neto; Edson Antonio Capello Sousa; José Henrique Rubo
Journal:  J Appl Oral Sci       Date:  2016-04       Impact factor: 2.698

3.  A strain gauge analysis comparing 4-unit veneered zirconium dioxide implant-borne fixed dental prosthesis on engaging and non-engaging abutments before and after torque application.

Authors:  Alyssa Epprecht; Marco Zeltner; Goran Benic; Mutlu Özcan
Journal:  Clin Exp Dent Res       Date:  2018-02-15