Literature DB >> 21039319

Effect of CT slice thickness on accuracy of implant positioning in navigated total hip arthroplasty.

N Hirasawa1, M Matsubara, K Ishii, S Hagio, N Okuda, I Sekiya, T Muneta.   

Abstract

There are many published reports demonstrating the accuracy of CT-based navigation systems. However, the use of such systems often subjects patients to a high level of radiation exposure. CT scans acquired using thinner slices are considered to lead to more accurate results, but also increase radiation exposure. We took the postoperative CT scans for 56 cases of total hip arthroplasty performed using a CT-based navigation system and analyzed the accuracy of the cup and stem positioning. Of these cases, 41 were performed using 3-mm CT slices and 15 were performed using 1-mm slices, enabling us to compare the accuracy of the system and the radiation exposure using the different slice thicknesses. CT-based navigation appears to be very accurate with regard to cup anteversion and leg length, but inaccurate with regard to stem anteversion. As for the varus/valgus angle of the stem, the navigated approach seems to be very accurate in terms of the numerical value, but this does not satisfy us: Stem anteversion is still inaccurate with this system, while cup inclination is sufficiently accurate with both navigation and manual methods. Use of 1-mm CT slices results in twice the radiation exposure associated with 3-mm CT slices, but there is little difference with respect to accuracy. It is therefore recommended to use a CT-based navigation system with 3-mm CT slices for accurate and safe total hip arthroplasty.

Entities:  

Mesh:

Year:  2010        PMID: 21039319     DOI: 10.3109/10929088.2010.525025

Source DB:  PubMed          Journal:  Comput Aided Surg        ISSN: 1092-9088


  3 in total

1.  Effect of improved navigation performance on the accuracy of implant placement in total hip arthroplasty with a CT-based navigation system.

Authors:  Ichiro Nakahara; Takayuki Kyo; Yasuo Kuroda; Hidenobu Miki
Journal:  J Artif Organs       Date:  2018-04-02       Impact factor: 1.731

2.  Image-Less THA Cup Navigation in Clinical Routine Setup: Individual Adjustments, Accuracy, Precision, and Robustness.

Authors:  Corinne A Zurmühle; Benjamin Zickmantel; Matthias Christen; Bernhard Christen; Guoyan Zheng; Joseph M Schwab; Moritz Tannast; Simon D Steppacher
Journal:  Medicina (Kaunas)       Date:  2022-06-20       Impact factor: 2.948

3.  A simple angle-measuring instrument for measuring cemented stem anteversion during total hip arthroplasty.

Authors:  Ryo Mitsutake; Hiromasa Tanino; Yasuhiro Nishida; Masaru Higa; Hiroshi Ito
Journal:  BMC Musculoskelet Disord       Date:  2020-02-19       Impact factor: 2.362

  3 in total