Literature DB >> 21037266

Eye tracking for assessment of workload: a pilot study in an anaesthesia simulator environment.

C M Schulz1, E Schneider, L Fritz, J Vockeroth, A Hapfelmeier, M Wasmaier, E F Kochs, G Schneider.   

Abstract

BACKGROUND: Workload assessment is an important tool for improving patient safety in anaesthesia. We tested the hypothesis that heart rate, pupil size, and duration of fixation increase, whereas saccade amplitude decreases with increased workload during simulated critical incidents.
METHODS: Fifteen trainee anaesthetists participated in this randomized cross-over trial. Each participant used a head-mounted eye-tracking device (EyeSeeCam) during induction of general anaesthesia in a full-scale simulation during three different sessions. No critical incident was simulated in the first session. In a randomized order, workload was increased by simulation of a critical incident in the second or third session. Pupil size, duration of fixations, saccadic amplitude, and heart rate of each participant and the simulator conditions were recorded continuously and synchronized. The data were analysed by paired sample t-tests and mixed-effects regression analysis.
RESULTS: The findings of the second and third sessions of 11 participants were analysed. Pupil diameter and heart rate increased simultaneously as the severity of the simulated critical incident increased. Allowing for individual effects, the simulator conditions explained 92.6% of the variance in pupil diameter and 93.6% of the variance in heart rate (both P<0.001). The duration of fixation decreased with increased workload. The saccadic amplitude remained unaffected by workload changes.
CONCLUSIONS: Pupil size and heart rate reflect workload increase within simulator sessions, but they do not permit overall workload comparisons between individuals or sessions. Contrary to our assumption, the duration of fixation decreased with increased workload. Saccade amplitude did not reflect workload fluctuations.

Entities:  

Mesh:

Year:  2010        PMID: 21037266     DOI: 10.1093/bja/aeq307

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  14 in total

Review 1.  A survey of context recognition in surgery.

Authors:  Igor Pernek; Alois Ferscha
Journal:  Med Biol Eng Comput       Date:  2017-07-10       Impact factor: 2.602

2.  Intraocular pressure increases after complex simulated surgical procedures in residents: an experimental study.

Authors:  Jesús Vera; Carolina Diaz-Piedra; Raimundo Jiménez; Jose M Sanchez-Carrion; Leandro L Di Stasi
Journal:  Surg Endosc       Date:  2018-07-02       Impact factor: 4.584

3.  The influence of anaesthetists' experience on workload, performance and visual attention during simulated critical incidents.

Authors:  Christian M Schulz; Erich Schneider; Stefan Kohlbecher; Alexander Hapfelmeier; Fabian Heuser; Klaus J Wagner; Eberhard F Kochs; Gerhard Schneider
Journal:  J Clin Monit Comput       Date:  2013-03-08       Impact factor: 2.502

4.  Self-reported ratings appear to be the best for workload measurement.

Authors:  Craig S Webster; Jennifer M Weller
Journal:  BMJ Simul Technol Enhanc Learn       Date:  2018-07-09

5.  Anaesthesia workload measurement devices: qualitative systematic review.

Authors:  Dalal S Almghairbi; Takawira C Marufu; Iain K Moppett
Journal:  BMJ Simul Technol Enhanc Learn       Date:  2018-07-09

6.  Improvement of design of a surgical interface using an eye tracking device.

Authors:  Duygun Erol Barkana; Alper Açık; Dilek Goksel Duru; Adil Deniz Duru
Journal:  Theor Biol Med Model       Date:  2014-05-07       Impact factor: 2.432

7.  Influence of Mental Workload on the Performance of Anesthesiologists during Induction of General Anesthesia: A Patient Simulator Study.

Authors:  Hitoshi Sato; Tetsuya Miyashita; Hiromasa Kawakami; Yusuke Nagamine; Shunsuke Takaki; Takahisa Goto
Journal:  Biomed Res Int       Date:  2016-04-11       Impact factor: 3.411

8.  Pupil diameter changes reflect difficulty and diagnostic accuracy during medical image interpretation.

Authors:  Tad T Brunyé; Marianna D Eddy; Ezgi Mercan; Kimberly H Allison; Donald L Weaver; Joann G Elmore
Journal:  BMC Med Inform Decis Mak       Date:  2016-07-05       Impact factor: 2.796

9.  The validity of linear and non-linear heart rate metrics as workload indicators of emergency physicians.

Authors:  Frederick Schneider; Jan Martin; Alexander Hapfelmeier; Denis Jordan; Gerhard Schneider; Christian M Schulz
Journal:  PLoS One       Date:  2017-11-30       Impact factor: 3.240

10.  The effect of multitasking on the communication skill and clinical skills of medical students.

Authors:  Bryony Woods; Aidan Byrne; Owen Bodger
Journal:  BMC Med Educ       Date:  2018-04-10       Impact factor: 2.463

View more