Literature DB >> 21031509

MRI of the neck at 3 Tesla using the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) (BLADE) sequence compared with T2-weighted fast spin-echo sequence.

Yoshimitsu Ohgiya1, Jumpei Suyama, Noritaka Seino, Shu Takaya, Masaaki Kawahara, Makoto Saiki, Syouei Sai, Masanori Hirose, Takehiko Gokan.   

Abstract

PURPOSE: To evaluate motion artifacts, tissue contrasts, and lesion detectability in the neck with the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) (BLADE) technique.
MATERIALS AND METHODS: A total of 46 patients referred for MRI of the neck were included in a comparison of T2-weighted BLADE (T2W-BLADE) sequence and T2W fast spin-echo (T2W-FSE) sequence. All examinations were performed at 3T using the same parameters. Two observers evaluated unlabelled images for motion artifacts, the preferred image quality, and lesion detectability. Region of interest (ROI)-based quantitative measurements were performed to assess tissue contrasts. The frequency of occurrence of the different assessed artifacts and the lesion detectability was tested using McNemar's test. Tissue contrasts were compared using the Wilcoxon paired test. Reader agreement was assessed using kappa test.
RESULTS: T2W-BLADE showed less ghosting and pulsation artifacts than T2W-FSE (P < 0.01). T2W-BLADE images were rated as better than or equal to T2W-FSE images in majority cases (93.5%; kappa = 0.64). There was not significant difference in tissue contrasts between T2W-BLADE and T2W-FSE. A total of 32 lesions were present in 32 patients and equally well seen on T2W-BLADE and T2W-FSE.
CONCLUSION: T2W-BLADE can reduce motion artifacts and provide tissue contrasts and lesion detectability equivalent to T2W-FSE.
© 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 21031509     DOI: 10.1002/jmri.22234

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  8 in total

1.  Elimination of motion and pulsation artifacts using BLADE sequences in shoulder MR imaging.

Authors:  E Lavdas; M Vlychou; E Zaloni; K Vassiou; A Tsagkalis; Z Dailiana; I Fezoulidis
Journal:  Skeletal Radiol       Date:  2015-08-26       Impact factor: 2.199

2.  Revised PROPELLER for T2-weighted imaging of the prostate at 3 Tesla: impact on lesion detection and PI-RADS classification.

Authors:  Michael Meier-Schroers; Christian Marx; Frederic Carsten Schmeel; Karsten Wolter; Jürgen Gieseke; Wolfgang Block; Alois Martin Sprinkart; Frank Traeber; Winfried Willinek; Hans Heinz Schild; Guido Matthias Kukuk
Journal:  Eur Radiol       Date:  2017-07-07       Impact factor: 5.315

3.  Efficacy of the radial acquisition regime (RADAR) for acquiring head and neck MR images.

Authors:  Tsukasa Kojima; Hidetake Yabuuchi; Hiroshi Narita; Seiji Kumazawa; Yuzo Yamasaki; Yuki Yano; Noriyuki Sakai; Yoichi Kurihara; Kiyoshi Hisada; Masafumi Masaki; Hiroshi Kimura
Journal:  Br J Radiol       Date:  2016-09-16       Impact factor: 3.039

4.  Heterogeneity analysis of diffusion-weighted MRI for prediction and assessment of microstructural changes early after one cycle of induction chemotherapy in nasopharyngeal cancer patients.

Authors:  Manijeh Beigi; Anahita Fathi Kazerooni; Mojtaba Safari; Marzieh Alamolhoda; Mohsen Shojaee Moghdam; Shiva Moghadam; Hamidreza SalighehRad; Ahmad Ameri
Journal:  Radiol Med       Date:  2017-09-15       Impact factor: 3.469

5.  The MR radiomic signature can predict preoperative lymph node metastasis in patients with esophageal cancer.

Authors:  Jinrong Qu; Chen Shen; Jianjun Qin; Zhaoqi Wang; Zhenyu Liu; Jia Guo; Hongkai Zhang; Pengrui Gao; Tianxia Bei; Yingshu Wang; Hui Liu; Ihab R Kamel; Jie Tian; Hailiang Li
Journal:  Eur Radiol       Date:  2018-07-23       Impact factor: 5.315

6.  Arterial hyperintensity on BLADE fluid-attenuated inversion recovery images (FLAIR) in hyperacute territorial infarction: comparison with conventional FLAIR.

Authors:  Eujean Kwag; Soo Mee Lim; Ji Eun Park; In Hye Chae
Journal:  Eur Radiol       Date:  2014-05-17       Impact factor: 5.315

7.  Diagnostic performance in T staging for patients with esophagogastric junction cancer using high-resolution MRI: a comparison with conventional MRI at 3 tesla.

Authors:  Yuan Yuan; Luguang Chen; Shengnan Ren; Zhen Wang; Yukun Chen; Aiguo Jin; Shuai Li; Xu Fang; Tiegong Wang; Yun Bian; Qingsong Yang; Chenguang Bai; Qiang Hao; Jianping Lu
Journal:  Cancer Imaging       Date:  2019-12-04       Impact factor: 3.909

8.  Periodically rotated overlapping parallel lines with enhanced reconstruction acquisition to improve motion-induced artifacts in bladder cancer imaging: Initial findings.

Authors:  Huyen Thanh Nguyen; Zarine Ketul Shah; Amir Mortazavi; Kamal S Pohar; Lai Wei; Debra Lyn Zynger; Michael Vinzenz Knopp
Journal:  Medicine (Baltimore)       Date:  2019-10       Impact factor: 1.817

  8 in total