Literature DB >> 21030743

An enhanced high-resolution EMCCD-based gamma camera using SiPM side detection.

J W T Heemskerk1, M A N Korevaar, J Huizenga, R Kreuger, D R Schaart, M C Goorden, F J Beekman.   

Abstract

Electron-multiplying charge-coupled devices (EMCCDs) coupled to scintillation crystals can be used for high-resolution imaging of gamma rays in scintillation counting mode. However, the detection of false events as a result of EMCCD noise deteriorates the spatial and energy resolution of these gamma cameras and creates a detrimental background in the reconstructed image. In order to improve the performance of an EMCCD-based gamma camera with a monolithic scintillation crystal, arrays of silicon photon-multipliers (SiPMs) can be mounted on the sides of the crystal to detect escaping scintillation photons, which are otherwise neglected. This will provide a priori knowledge about the correct number and energies of gamma interactions that are to be detected in each CCD frame. This information can be used as an additional detection criterion, e.g. for the rejection of otherwise falsely detected events. The method was tested using a gamma camera based on a back-illuminated EMCCD, coupled to a 3 mm thick continuous CsI:Tl crystal. Twelve SiPMs have been mounted on the sides of the CsI:Tl crystal. When the information of the SiPMs is used to select scintillation events in the EMCCD image, the background level for (99m)Tc is reduced by a factor of 2. Furthermore, the SiPMs enable detection of (125)I scintillations. A hybrid SiPM-/EMCCD-based gamma camera thus offers great potential for applications such as in vivo imaging of gamma emitters.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21030743     DOI: 10.1088/0031-9155/55/22/011

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  A Prototype Detector for a Novel High-Resolution PET System: BazookaPET.

Authors:  Ryeojin Park; Brian W Miller; Abhinav K Jha; Lars R Furenlid; William C J Hunter; Harrison H Barrett
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2012 Oct-Nov

Review 2.  SPECT detectors: the Anger Camera and beyond.

Authors:  Todd E Peterson; Lars R Furenlid
Journal:  Phys Med Biol       Date:  2011-08-09       Impact factor: 3.609

3.  An experimental comparison of two different technetium source activities which can imitate thyroid scintigraphy in case of thyroid toxic nodule.

Authors:  Ramë Miftari; Ferki Fejza; Xhavit Bicaj; Adem Nura; Valdete Topciu; Ismet Bajrami
Journal:  Acta Inform Med       Date:  2014-04
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.