Literature DB >> 21030270

The influence of the muscle fiber pennation angle and innervation zone on the identification of neuromuscular fatigue during cycle ergometry.

Clayton L Camic1, Terry J Housh, C Russell Hendrix, Jorge M Zuniga, Haley C Bergstrom, Richard J Schmidt, Glen O Johnson.   

Abstract

The purpose of the present investigation was to compare the electromyographic (EMG) responses and the estimated physical working capacity at the fatigue threshold (PWC(FT)) values recorded from electrode arrangements placed: (1) parallel to the muscle fiber pennation angle (MFPA), (2) parallel to the long axis of the femur, and (3) over the innervation zone (IZ) during incremental cycle ergometry. Thirteen college-aged males and females (mean age ± SD=22.4 ± 3.4 years) performed an incremental test to exhaustion on a cycle ergometer. A linear electrode array was utilized to determine the MFPA and location of the IZ of the vastus lateralis (VL). For determination of the PWC(FT) values, EMG signals were recorded from three bipolar electrode arrangements at different locations over the VL. The results of a one-way repeated measures ANOVA indicated there were no significant (p<0.05) mean differences in PWC(FT) values among the electrode arrangements (parallel to the MFPA=190 ± 36 W; parallel to the long axis of the femur=194 ± 40 W; and over the IZ=199 ± 51 W) or the EMG amplitude and MPF values at the common power outputs. There were also significant correlations (r=0.75-0.91) among the three electrode arrangements for PWC(FT) values. These findings suggested that the PWC(FT), like absolute EMG amplitude and MPF, is robust to the influence of electrode placement over the IZ as well as the orientation with respect to the MFPA during cycle ergometry.
Copyright © 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 21030270     DOI: 10.1016/j.jelekin.2010.09.010

Source DB:  PubMed          Journal:  J Electromyogr Kinesiol        ISSN: 1050-6411            Impact factor:   2.368


  4 in total

1.  Determining The Electromyographic Fatigue Threshold Following a Single Visit Exercise Test.

Authors:  Sujay S Galen; Darren R Guffey; Jared W Coburn; Moh H Malek
Journal:  J Vis Exp       Date:  2015-07-27       Impact factor: 1.355

2.  Isometric-based EMG threshold in girls and women.

Authors:  Stacey Woods; Raffy Dotan; Nicole Jenicek; Bareket Falk
Journal:  Eur J Appl Physiol       Date:  2020-03-02       Impact factor: 3.078

3.  Influence of amplitude cancellation on the accuracy of determining the onset of muscle activity from the surface electromyogram.

Authors:  Mark Jesunathadas; Sameer S Aidoor; Kevin G Keenan; Dario Farina; Roger M Enoka
Journal:  J Electromyogr Kinesiol       Date:  2012-02-12       Impact factor: 2.368

4.  Skeletal muscle oxygenation during cycling at different power output and cadence.

Authors:  Lisha Shastri; Mariana Alkhalil; Claire Forbes; Tina El-Wadi; Gerrard Rafferty; Koji Ishida; Federico Formenti
Journal:  Physiol Rep       Date:  2019-02
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.