Literature DB >> 20980168

Evaluation of formation of granulation tissue caused by metallic stent placement in a rat urethral model.

Yong-Dong Li1, Ho-Young Song, Jin Hyoung Kim, Cheol-Woong Woo, Jung-Hoon Park, Tae-Hyung Kim, Gyungyub Gong.   

Abstract

PURPOSE: To evaluate the feasibility of metallic stent placement and the formation of granulation tissue caused by stent placement in a rat urethral model.
MATERIALS AND METHODS: A bare self-expanding metallic stent was inserted in the urethra under fluoroscopic guidance in 20 male Sprague-Dawley rats. Ten rats were euthanized at 4 weeks (group A), and the other 10 were euthanized at 8 weeks after stent placement (group B). Stenosis diameter, number of epithelial layers, degree of inflammatory cell infiltration, thickness of submucosal fibrosis, and percentage of granulation tissue area were assessed.
RESULTS: Stent placement was technically successful in all rats. Urethrograms showed perforation in three rats, partial migration in three, and stone formation in four. Granulation tissue formation was observed in all rats at the stent-implanted urethra, and the average percentage of granulation tissue area accounted for 41% and 45% of the original urethral lumen area in groups A and B, respectively. Urethrograms and urethral specimens showed significantly less stenosis diameter, less thickness of submucosal fibrosis, and lower percentage of granulation tissue area in the proximal urethra than in the distal urethra in both groups (P < .05). Histologic results demonstrated significantly fewer epithelial layers in group B compared with group A (P = .028).
CONCLUSIONS: Placement of a self-expandable metallic stent proved to be feasible in the rat urethra and an efficient approach to stimulate granulation tissue formation as a potential model for reproducing the mechanisms of restenosis.
Copyright © 2010 SIR. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20980168     DOI: 10.1016/j.jvir.2010.07.026

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  1 in total

1.  Comparison of three kinds of self-expandable metallic stents induced granulation tissue hyperplasia in the rabbit trachea.

Authors:  Yahua Li; Mengde Li; Xiaofeng Wang; Yuhui Wang; Chang Li; Yanan Zhao; Zhaonan Li; Jianjian Chen; Jing Li; Kewei Ren; Zongming Li; Jianzhuang Ren; Xinwei Han; Qian Li
Journal:  Sci Rep       Date:  2021-11-30       Impact factor: 4.379

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.