Literature DB >> 20980162

A rat tracheal model to investigate stent-induced tissue hyperplasia: a pilot study.

Ji Hoon Shin1, Kyu-Bo Sung, Eun-Young Kim, Dong-Ho Shin, Ho-Young Song.   

Abstract

PURPOSE: To evaluate the feasibility of stent placement and the formation of stent-induced tissue hyperplasia and to verify matrix metalloproteinase (MMP) expression in stent-induced tissue hyperplasia in a rat tracheal model.
MATERIALS AND METHODS: In a pilot study, four rats were used to verify MMP expression in stent-induced tracheal tissue hyperplasia based on zymography and Western blot analysis. In the main experiment, 12 rats were divided into two groups with different stent-mesh gap sizes (group I, 1.23 × 1.92 mm; group II, 0.80 × 1.80 mm). The stent was 4 mm in diameter and 8 mm long. Follow-up tracheogram was performed before sacrifice 3 weeks after stent placement. The gross and the microscopic findings were evaluated.
RESULTS: Stent placement was technically successful in all rats. During follow-up, two rats (one from each group) died within 4 days after stent placement, and one stent in group II was placed outside the trachea. MMP-9 expression was significantly higher in tissue hyperplasia than in control normal tissue. The excised specimens showed tissue hyperplasia through the mesh, and all of the stents had become incorporated into the wall of the trachea. The papillary projection thickness, granulation tissue area, percentage of granulation tissue area, and degree of inflammatory cell infiltration were higher in group II than in group I, but there was no statistically significant difference.
CONCLUSIONS: In this study, stent placement was feasible, and the formation of stent-induced tissue hyperplasia was evident in a rat tracheal model. MMP-9 overexpression was evident in the stent-induced tracheal tissue hyperplasia.
Copyright © 2010 SIR. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20980162     DOI: 10.1016/j.jvir.2010.09.007

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  2 in total

1.  Comparison of three kinds of self-expandable metallic stents induced granulation tissue hyperplasia in the rabbit trachea.

Authors:  Yahua Li; Mengde Li; Xiaofeng Wang; Yuhui Wang; Chang Li; Yanan Zhao; Zhaonan Li; Jianjian Chen; Jing Li; Kewei Ren; Zongming Li; Jianzhuang Ren; Xinwei Han; Qian Li
Journal:  Sci Rep       Date:  2021-11-30       Impact factor: 4.379

2.  A Comparison of a Fully Covered and an Uncovered Segmented Biodegradable Esophageal Stent in a Porcine Model: Preclinical Evaluation of Degradation, Complications, and Tissue Reactions.

Authors:  Yadong Feng; Chunhua Jiao; Yang Cao; Ye Zhao; Yanfang Chen; Lin Fang; Ruihua Shi
Journal:  Gastroenterol Res Pract       Date:  2016-02-28       Impact factor: 2.260

  2 in total