Literature DB >> 20975987

Mechanical and Electronic Approaches to Improve the Sensitivity of Microcantilever Sensors.

Madhu Santosh Ku Mutyala1, Deepika Bandhanadham, Liu Pan, Vijaya Rohini Pendyala, Hai-Feng Ji.   

Abstract

Advances in the field of Micro Electro Mechanical Systems (MEMS) and their uses now offer unique opportunities in the design of ultrasensitive analytical tools. The analytical community continues to search for cost-effective, reliable, and even portable analytical techniques that can give reliable and fast response results for a variety of chemicals and biomolecules. Microcantilevers (MCLs) have emerged as a unique platform for label-free biosensor or bioassay. Several electronic designs, including piezoresistive, piezoelectric, and capacitive approaches, have been applied to measure the bending or frequency change of the MCLs upon exposure to chemicals. This review summarizes mechanical, fabrication, and electronics approaches to increase the sensitivity of microcantilever (MCL) sensors.

Entities:  

Year:  2009        PMID: 20975987      PMCID: PMC2958108          DOI: 10.1007/s10409-008-0222-6

Source DB:  PubMed          Journal:  Acta Mech Sin        ISSN: 0567-7718            Impact factor:   1.975


  1 in total

1.  A femtogram resolution mass sensor platform, based on SOI electrostatically driven resonant cantilever. Part I: electromechanical model and parameter extraction.

Authors:  J Teva; G Abadal; F Torres; J Verd; F Pérez-Murano; N Barniol
Journal:  Ultramicroscopy       Date:  2006-04-18       Impact factor: 2.689

  1 in total
  6 in total

1.  Microcantilevers modified by specific peptide for selective detection of trimethylamine.

Authors:  Xin Huang; Mingfu Li; Xiaohe Xu; Hongjun Chen; Hai-Feng Ji; Shuifang Zhu
Journal:  Biosens Bioelectron       Date:  2011-09-16       Impact factor: 10.618

Review 2.  Approaches to increasing surface stress for improving signal-to-noise ratio of microcantilever sensors.

Authors:  Hai-Feng Ji; Benjamin D Armon
Journal:  Anal Chem       Date:  2010-03-01       Impact factor: 6.986

3.  Investigation of the frequency shift of a SAD circuit loop and the internal micro-cantilever in a gas sensor.

Authors:  Liu Guan; Jiahao Zhao; Shijie Yu; Peng Li; Zheng You
Journal:  Sensors (Basel)       Date:  2010-07-23       Impact factor: 3.576

4.  Electrostatic excitation for the force amplification of microcantilever sensors.

Authors:  Ali Shokuhfar; Payam Heydari; Salman Ebrahimi-Nejad
Journal:  Sensors (Basel)       Date:  2011-10-25       Impact factor: 3.576

5.  Analysis of the Dynamic Characteristics of a Micro-Piezoelectric Bimorph Beam Based on an Admittance Test.

Authors:  Tianxiang Zheng; Shuo Chen; Linxu Lei; Zhanfeng Deng; Cheng Zhang; Xing Yang; Haodong Zou; Menghan Xu
Journal:  Micromachines (Basel)       Date:  2017-07-14       Impact factor: 2.891

Review 6.  Capacitive Based Micromachined Resonators for Low Level Mass Detection.

Authors:  Muhammad Umair Nathani; Haleh Nazemi; Calvin Love; Yameema Babu Lopez; Siddharth Swaminathan; Arezoo Emadi
Journal:  Micromachines (Basel)       Date:  2020-12-25       Impact factor: 2.891

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.