Literature DB >> 20975215

Development of diamond-based X-ray detection for high-flux beamline diagnostics.

Jen Bohon1, Erik Muller, John Smedley.   

Abstract

High-quality single-crystal and polycrystalline chemical-vapor-deposition diamond detectors with platinum contacts have been tested at the white-beam X28C beamline at the National Synchrotron Light Source under high-flux conditions. The voltage dependence of these devices has been measured under both DC and pulsed-bias conditions, establishing the presence or absence of photoconductive gain in each device. Linear response consistent with the theoretically determined ionization energy has been achieved over eleven orders of magnitude when combined with previous low-flux studies. Temporal measurements with single-crystal diamond detectors have resolved the nanosecond-scale pulse structures of both the NSLS and the APS. Prototype single-crystal quadrant detectors have provided the ability to simultaneously resolve the X-ray beam position and obtain a quantitative measurement of the flux.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20975215      PMCID: PMC3089012          DOI: 10.1107/S0909049510031420

Source DB:  PubMed          Journal:  J Synchrotron Radiat        ISSN: 0909-0495            Impact factor:   2.616


  2 in total

1.  CVD diamond-based semi-transparent beam-position monitors for synchrotron beamlines: preliminary studies and device developments at CEA/Saclay.

Authors:  P Bergonzo; D Tromson; C Mer
Journal:  J Synchrotron Radiat       Date:  2006-02-17       Impact factor: 2.616

2.  Installation and testing of a focusing mirror at beamline X28C for high flux x-ray radiolysis of biological macromolecules.

Authors:  Michael R Sullivan; Sandeep Rekhi; Jen Bohon; Sayan Gupta; Donald Abel; John Toomey; Mark R Chance
Journal:  Rev Sci Instrum       Date:  2008-02       Impact factor: 1.523

  2 in total
  8 in total

1.  Transmission-mode diamond white-beam position monitor at NSLS.

Authors:  Erik M Muller; John Smedley; Jen Bohon; Xi Yang; Mengjia Gaowei; John Skinner; Gianluigi De Geronimo; Michael Sullivan; Marc Allaire; Jeffrey W Keister; Lonny Berman; Annie Héroux
Journal:  J Synchrotron Radiat       Date:  2012-03-17       Impact factor: 2.616

2.  Pixelated transmission-mode diamond X-ray detector.

Authors:  Tianyi Zhou; Wenxiang Ding; Mengjia Gaowei; Gianluigi De Geronimo; Jen Bohon; John Smedley; Erik Muller
Journal:  J Synchrotron Radiat       Date:  2015-09-29       Impact factor: 2.616

Review 3.  Predicting data quality in biological X-ray solution scattering.

Authors:  Chenzheng Wang; Yuexia Lin; Devin Bougie; Richard E Gillilan
Journal:  Acta Crystallogr D Struct Biol       Date:  2018-07-24       Impact factor: 7.652

4.  Time-Resolved Hydroxyl Radical Footprinting of RNA with X-Rays.

Authors:  Yumeng Hao; Jen Bohon; Ryan Hulscher; Mollie C Rappé; Sayan Gupta; Tadepalli Adilakshmi; Sarah A Woodson
Journal:  Curr Protoc Nucleic Acid Chem       Date:  2018-06-07

5.  A single-crystal diamond X-ray pixel detector with embedded graphitic electrodes.

Authors:  C Bloomer; M E Newton; G Rehm; P S Salter
Journal:  J Synchrotron Radiat       Date:  2020-03-31       Impact factor: 2.616

6.  The XFP (17-BM) beamline for X-ray footprinting at NSLS-II.

Authors:  Awuri Asuru; Erik R Farquhar; Michael Sullivan; Donald Abel; John Toomey; Mark R Chance; Jen Bohon
Journal:  J Synchrotron Radiat       Date:  2019-06-04       Impact factor: 2.616

7.  Proton radiation effects on carrier transport in diamond radiation detectors.

Authors:  Mengnan Zou; Jen Bohon; John Smedley; James Distel; Kyle Schmitt; Ren-Yuan Zhu; Liyuan Zhang; Erik M Muller
Journal:  AIP Adv       Date:  2020-02-03       Impact factor: 1.548

8.  Transmission measurement at the Bernina branch of the Aramis Beamline of SwissFEL.

Authors:  Pavle Juranic; Kai Tiedtke; Shigeki Owada; Takahiro Tanaka; Ulf Jastrow; Andrey Sorokin; Luc Patthey; Roman Mankowsky; Markus Degenhardt; Yunieski Arbelo; Christopher Arrell; John Smedley; Jen Bohon; Rolf Follath
Journal:  J Synchrotron Radiat       Date:  2019-10-23       Impact factor: 2.616

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.