Literature DB >> 20963623

The orthotropic viscoelastic behavior of aortic elastin.

Yu Zou1, Yanhang Zhang.   

Abstract

In this paper, we studied the viscoelastic behaviors of isolated aortic elastin using combined modeling and experimental approaches. Biaxial stress relaxation and creep experiments were performed to study the time-dependent behavior of elastin. Experimental results reveal that stress relaxation preconditioning is necessary in order to obtain repeatable stress relaxation responses. Elastin exhibits less stress relaxation than intact or decellularized aorta. The rate of stress relaxation of intact and decellularized aorta is linearly dependent on the initial stress levels. The rate of stress relaxation for elastin increases linearly at stress levels below about 60 kPa; however, the rate changes very slightly at higher initial stress levels. Experimental results also show that creep response is negligible for elastin, and the intact or decellularized aorta. A quasi-linear viscoelasticity model was incorporated into a statistical mechanics based eight-chain microstructural model at the fiber level to simulate the orthotropic viscoelastic behavior of elastin. A user material subroutine was developed for finite element analysis. Results demonstrate that this model is suitable to capture both the orthotropic hyperelasticity and viscoelasticity of elastin.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20963623     DOI: 10.1007/s10237-010-0260-4

Source DB:  PubMed          Journal:  Biomech Model Mechanobiol        ISSN: 1617-7940


  17 in total

1.  Crosslinked elastic fibers are necessary for low energy loss in the ascending aorta.

Authors:  Jungsil Kim; Marius Catalin Staiculescu; Austin J Cocciolone; Hiromi Yanagisawa; Robert P Mecham; Jessica E Wagenseil
Journal:  J Biomech       Date:  2017-07-25       Impact factor: 2.712

2.  An experimental and modeling study of the viscoelastic behavior of collagen gel.

Authors:  Bin Xu; Haiyue Li; Yanhang Zhang
Journal:  J Biomech Eng       Date:  2013-05       Impact factor: 2.097

3.  Mechanical Properties of Arterial Elastin With Water Loss.

Authors:  Yunjie Wang; Jacob Hahn; Yanhang Zhang
Journal:  J Biomech Eng       Date:  2018-04-01       Impact factor: 2.097

4.  Effect of acute high-intensity resistance exercise on optic nerve sheath diameter and ophthalmic artery blood flow pulsatility.

Authors:  W K Lefferts; W E Hughes; K S Heffernan
Journal:  J Hum Hypertens       Date:  2015-03-05       Impact factor: 3.012

5.  Glycosaminoglycans contribute to extracellular matrix fiber recruitment and arterial wall mechanics.

Authors:  Jeffrey M Mattson; Raphaël Turcotte; Yanhang Zhang
Journal:  Biomech Model Mechanobiol       Date:  2016-08-04

6.  Mechanical evaluation of decellularized porcine thoracic aorta.

Authors:  Yu Zou; Yanhang Zhang
Journal:  J Surg Res       Date:  2011-04-21       Impact factor: 2.192

7.  The effect of aortic wall and aortic leaflet stiffening on coronary hemodynamic: a fluid-structure interaction study.

Authors:  S Nobari; R Mongrain; R Leask; R Cartier
Journal:  Med Biol Eng Comput       Date:  2013-04-03       Impact factor: 2.602

8.  Mechanical, structural, and dynamical modifications of cholesterol exposed porcine aortic elastin.

Authors:  Kubra Bilici; Steven W Morgan; Moshe C Silverstein; Yunjie Wang; Hyung Jin Sun; Yanhang Zhang; Gregory S Boutis
Journal:  Biophys Chem       Date:  2016-09-09       Impact factor: 2.352

9.  Multi-scale Modeling of the Cardiovascular System: Disease Development, Progression, and Clinical Intervention.

Authors:  Yanhang Zhang; Victor H Barocas; Scott A Berceli; Colleen E Clancy; David M Eckmann; Marc Garbey; Ghassan S Kassab; Donna R Lochner; Andrew D McCulloch; Roger Tran-Son-Tay; Natalia A Trayanova
Journal:  Ann Biomed Eng       Date:  2016-05-02       Impact factor: 3.934

10.  Arterial mechanics considering the structural and mechanical contributions of ECM constituents.

Authors:  Yunjie Wang; Shahrokh Zeinali-Davarani; Yanhang Zhang
Journal:  J Biomech       Date:  2016-02-24       Impact factor: 2.712

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.