Literature DB >> 2096205

Clinical assessment of blood pressure.

D W McKay1, N R Campbell, L S Parab, A Chockalingam, J G Fodor.   

Abstract

This study was performed to determine the blood pressure measuring techniques and accuracy of sphygmomanometers used by physicians in ambulatory care clinics on the Avalon Peninsula of Newfoundland. Of the 114 participating physicians, no physician completely followed all the recommended BP measuring techniques of the American Heart Association. Almost all physicians supported the patient's arm at heart level to measure BP. Fewer physicians used the following recommended techniques; palpation to initially assess systolic BP (38%), measurement of BP in both arms (23%), an appropriate rate of cuff deflation (18%), measurement of BP in recommended patient positions (10%), the appropriate length of rest (4%) or use of a cuff of appropriate size (3%). Approximately 8% of mercury sphygmomanometers were out of calibration by at least 4 mmHg but none were out by more than 6 mmHg. Forty percent of aneroid sphygmomanometers were out of calibration by at least 4 mmHg and of these 30% were out by 10 mmHg or more. Mercury and aneroid sphygmomanometers were used by 60% of physicians. Aneroid sphygmomanometers were used exclusively by 34% of physicians, while 5% of physicians relied solely on mercury devices. Standardized techniques for BP measurement are not used and inaccurate sphygmomanometers are common; these factors may lead to misclassification of blood pressure and inappropriate treatment of patients.

Entities:  

Mesh:

Year:  1990        PMID: 2096205

Source DB:  PubMed          Journal:  J Hum Hypertens        ISSN: 0950-9240            Impact factor:   3.012


  25 in total

Review 1.  Evidence based treatment of hypertension. Measurement of blood pressure: an evidence based review.

Authors:  F A McAlister; S E Straus
Journal:  BMJ       Date:  2001-04-14

2.  Diagnosis and treatment of high blood pressure. New directions and new approaches: 1999 Canadian recommendations for management of hypertension.

Authors:  R J Petrella
Journal:  Can Fam Physician       Date:  2000-07       Impact factor: 3.275

3.  Accurate blood pressure measurements and the other arm: the doctor is ultimately responsible.

Authors:  Herbert L Fred
Journal:  Tex Heart Inst J       Date:  2013

4.  Knowledge of accurate blood pressure measurement procedures in chiropractic students.

Authors:  Angela M Crosley; James R La Rose
Journal:  J Chiropr Educ       Date:  2013-06-27

5.  Validating prediction equations for mid-arm circumference measurements in adults: National Health and Nutrition Examination Survey, 2001-2012.

Authors:  Tatiana Nwankwo; Yechiam Ostchega; Guangyu Zhang; Jeffery P Hughes
Journal:  Blood Press Monit       Date:  2015-06       Impact factor: 1.444

6.  Hypertension management in Canada: good news, but important challenges remain.

Authors:  Sailesh Mohan; Norm R C Campbell
Journal:  CMAJ       Date:  2008-05-20       Impact factor: 8.262

7.  Clinical problem solving based on the 1999 Canadian recommendations for the management of hypertension.

Authors:  R D Feldman; N R Campbell; P Larochelle
Journal:  CMAJ       Date:  1999       Impact factor: 8.262

8.  1999 Canadian recommendations for the management of hypertension. Task Force for the Development of the 1999 Canadian Recommendations for the Management of Hypertension.

Authors:  R D Feldman; N Campbell; P Larochelle; P Bolli; E D Burgess; S G Carruthers; J S Floras; R B Haynes; G Honos; F H Leenen; L A Leiter; A G Logan; M G Myers; J D Spence; K B Zarnke
Journal:  CMAJ       Date:  1999       Impact factor: 8.262

9.  Age-related differences in simultaneous interarm blood pressure measurements.

Authors:  M D Fotherby; B Panayiotou; J F Potter
Journal:  Postgrad Med J       Date:  1993-03       Impact factor: 2.401

Review 10.  Report of the Canadian Hypertension Society Consensus Conference: 2. Diagnosis of hypertension in adults.

Authors:  R B Haynes; Y Lacourcière; S W Rabkin; F H Leenen; A G Logan; N Wright; C E Evans
Journal:  CMAJ       Date:  1993-08-15       Impact factor: 8.262

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.