Literature DB >> 20958278

Comparison of the LMA Supreme vs the i-gel in paralysed patients undergoing gynaecological laparoscopic surgery with controlled ventilation.

W H L Teoh1, K M Lee, T Suhitharan, Z Yahaya, M M Teo, A T H Sia.   

Abstract

We compared the efficacy of the inflatable cuff of the LMA Supreme against the non-inflatable i-gel cuff in providing an adequate seal for laparoscopic surgery in the Trendelenburg position in 100 female patients. There was no difference in our primary outcome, oropharyngeal leak pressure, between the LMA Supreme and the i-gel (mean (SD) 26.4 (5.1) vs 25.0 (5.7) cmH(2) O, respectively; p = 0.18). Forty-seven (94%) LMA Supremes and 48 (96%) i-gels were successfully inserted on the first attempt, with similar ease, and comparable times to the first capnograph trace (mean (SD) 14.3 (4.7) s for the LMA Supreme vs 15.4 (8.2) s for the i-gel; p = 0.4). Gastric tube insertion was easier and achieved more quickly with the LMA Supreme vs the i-gel (9.0 (2.5) s vs 15.1 (7.3) s, respectively; p < 0.001). After creation of the pneumoperitoneum, there was a smaller difference between expired and inspired tidal volumes with the LMA Supreme (21.5 (15.2) ml) than with the i-gel (31.2 (23.5) ml; p = 0.009). There was blood on removal of two LMA Supremes and one i-gel. Four patients in the LMA Supreme group and one patient in the i-gel group experienced mild postoperative sore throat.

Entities:  

Mesh:

Year:  2010        PMID: 20958278     DOI: 10.1111/j.1365-2044.2010.06534.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  34 in total

1.  Comparison of LM-Supreme™ and endotracheal tube in patients undergoing gynecological laparoscopic surgery.

Authors:  Bahar Kuvaki; Şule Özbilgin; Sakize Ferim Günenç; Burcu Ataseven Küçük
Journal:  J Clin Monit Comput       Date:  2019-04-09       Impact factor: 2.502

2.  A randomized clinical study on postoperative pain comparing between the supraglottic airway device and endotracheal tubing in transabdominal preperitoneal repair (TAPP).

Authors:  Y Nagahisa; K Hashida; R Matsumoto; R Kawashima; M Okabe; K Kawamoto
Journal:  Hernia       Date:  2017-02-13       Impact factor: 4.739

Review 3.  [Second generation laryngeal masks : expanded indications].

Authors:  A Timmermann; E A Nickel; F Pühringer
Journal:  Anaesthesist       Date:  2015-01       Impact factor: 1.041

4.  A randomized comparison of the Ambu AuraGain versus the LMA supreme in patients undergoing gynaecologic laparoscopic surgery.

Authors:  Ana M Lopez; Merce Agusti; Pedro Gambus; Montserrat Pons; Teresa Anglada; Ricard Valero
Journal:  J Clin Monit Comput       Date:  2016-11-26       Impact factor: 2.502

5.  Comparison of the clinical performance of i-gel, LMA Supreme and LMA ProSeal in elective surgery.

Authors:  Geoffrey Haw Chieh Liew; Esther Dawen Yu; Shitalkumar Sharad Shah; Harikrishnan Kothandan
Journal:  Singapore Med J       Date:  2016-08       Impact factor: 1.858

6.  Positive end-expiratory pressure increases arterial oxygenation in elderly patients undergoing urological surgery using laryngeal mask airway in lithotomy position.

Authors:  Doo-Hwan Kim; Jun-Young Park; Jihion Yu; Gi-Ho Koh; Eunkyul Kim; Jai-Hyun Hwang; Young-Kug Kim
Journal:  J Clin Monit Comput       Date:  2019-02-20       Impact factor: 2.502

Review 7.  Role of laryngeal mask airway in laparoscopic cholecystectomy.

Authors:  José M Beleña; Ernesto Josué Ochoa; Mónica Núñez; Carlos Gilsanz; Alfonso Vidal
Journal:  World J Gastrointest Surg       Date:  2015-11-27

8.  Randomized comparison of the i-gel™, the LMA Supreme™, and the Laryngeal Tube Suction-D using clinical and fibreoptic assessments in elective patients.

Authors:  Sebastian G Russo; Stephan Cremer; Tamara Galli; Christoph Eich; Anselm Bräuer; Thomas A Crozier; Martin Bauer; Micha Strack
Journal:  BMC Anesthesiol       Date:  2012-08-07       Impact factor: 2.217

9.  The comparison of ProSeal and I-gel laryngeal mask airways in anesthetized adult patients under controlled ventilation.

Authors:  Osman Ekinci; Süheyla Abitagaoglu; Güldem Turan; Zübeyir Sivrikaya; Gülşen Bosna; Asu Özgultekin
Journal:  Saudi Med J       Date:  2015-04       Impact factor: 1.484

10.  Effect of pneumoperitoneum and Trendelenberg position on oropharyngeal sealing pressure of I-gel™ and ProSeal LMA™ in laparoscopic gynecological surgery: A randomized controlled trial.

Authors:  Sandeep Kumar Mishra; B Sivaraman; Hemavathy Balachander; Mahesh Naggappa; Satyen Parida; Ravindra R Bhat; Kotteeswaran Yuvaraj
Journal:  Anesth Essays Res       Date:  2015 Sep-Dec
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.