Maximum diameter measurements of aortic aneurysms on axial CT images after endovascular aneurysm repair: sufficient for follow-up?

Stephan Baumueller1, Thi Dan Linh Nguyen, Robert Paul Goetti, Mario Lachat, Burkhardt Seifert, Thomas Pfammatter, Thomas Frauenfelder.   

Abstract

PURPOSE: To assess the accuracy of maximum diameter measurements of aortic aneurysms after endovascular aneurysm repair (EVAR) on axial computed tomographic (CT) images in comparison to maximum diameter measurements perpendicular to the intravascular centerline for follow-up by using three-dimensional (3D) volume measurements as the reference standard.
MATERIALS AND METHODS: Forty-nine consecutive patients (73 ± 7.5 years, range 51-88 years), who underwent EVAR of an infrarenal aortic aneurysm were retrospectively included. Two blinded readers twice independently measured the maximum aneurysm diameter on axial CT images performed at discharge, and at 1 and 2 years after intervention. The maximum diameter perpendicular to the centerline was automatically measured. Volumes of the aortic aneurysms were calculated by dedicated semiautomated 3D segmentation software (3surgery, 3mensio, the Netherlands). Changes in diameter of 0.5 cm and in volume of 10% were considered clinically significant. Intra- and interobserver agreements were calculated by intraclass correlations (ICC) in a random effects analysis of variance. The two unidimensional measurement methods were correlated to the reference standard.
RESULTS: Intra- and interobserver agreements for maximum aneurysm diameter measurements were excellent (ICC = 0.98 and ICC = 0.96, respectively). There was an excellent correlation between maximum aneurysm diameters measured on axial CT images and 3D volume measurements (r = 0.93, P < 0.001) as well as between maximum diameter measurements perpendicular to the centerline and 3D volume measurements (r = 0.93, P < 0.001).
CONCLUSION: Measurements of maximum aneurysm diameters on axial CT images are an accurate, reliable, and robust method for follow-up after EVAR and can be used in daily routine.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20945067     DOI: 10.1007/s00270-010-9992-x

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  3 in total

1.  On growth measurements of abdominal aortic aneurysms using maximally inscribed spheres.

Authors:  H Gharahi; B A Zambrano; C Lim; J Choi; W Lee; S Baek
Journal:  Med Eng Phys       Date:  2015-05-23       Impact factor: 2.242

2.  Evaluation the Aortic Aneurysm Remodeling After a Successful Stentgraft Implantation.

Authors:  Monika Nowicka; Agnieszka Kowalczyk; Grażyna Rusak; Przemysław Ratajczak; Bartosz Sobociński
Journal:  Pol J Radiol       Date:  2016-10-13

3.  Comparability of semiautomatic tortuosity measurements in the carotid artery.

Authors:  Evelien E de Vries; Vanessa E C Pourier; Constance J H C M van Laarhoven; Evert J Vonken; Joost A van Herwaarden; Gert J de Borst
Journal:  Neuroradiology       Date:  2018-10-18       Impact factor: 2.804

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.