Literature DB >> 20941742

Carotid plaque assessment using fast 3D isotropic resolution black-blood MRI.

Niranjan Balu1, Vasily L Yarnykh, Baocheng Chu, Jinnan Wang, Thomas Hatsukami, Chun Yuan.   

Abstract

Black-blood MRI is a promising tool for carotid atherosclerotic plaque burden assessment and compositional analysis. However, current sequences are limited by large slice thickness. Accuracy of measurement can be improved by moving to isotropic imaging but can be challenging for patient compliance due to long scan times. We present a fast isotropic high spatial resolution (0.7×0.7×0.7 mm3) three-dimensional black-blood sequence (3D-MERGE) covering the entire cervical carotid arteries within 2 min thus ensuring patient compliance and diagnostic image quality. The sequence is optimized for vessel wall imaging of the carotid bifurcation based on its signal properties. The optimized sequence is validated on patients with significant carotid plaque. Quantitative plaque morphology measurements and signal-to-noise ratio measures show that 3D-MERGE provides good blood suppression and comparable plaque burden measurements to existing MRI protocols. 3D-MERGE is a promising new tool for fast and accurate plaque burden assessment in patients with atherosclerotic plaque.
Copyright © 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 20941742      PMCID: PMC3042490          DOI: 10.1002/mrm.22642

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  28 in total

1.  Improved efficiency in double-inversion fast spin-echo imaging.

Authors:  Dennis L Parker; K Craig Goodrich; Marilyn Masiker; Jay S Tsuruda; Gregory L Katzman
Journal:  Magn Reson Med       Date:  2002-05       Impact factor: 4.668

2.  Multislice double inversion pulse sequence for efficient black-blood MRI.

Authors:  Hee Kwon Song; Alexander C Wright; Ronald L Wolf; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2002-03       Impact factor: 4.668

3.  Multislice double inversion-recovery black-blood imaging with simultaneous slice reinversion.

Authors:  Vasily L Yarnykh; Chun Yuan
Journal:  J Magn Reson Imaging       Date:  2003-04       Impact factor: 4.813

4.  Volume-selective 3D turbo spin echo imaging for vascular wall imaging and distensibility measurement.

Authors:  Lindsey A Crowe; Peter Gatehouse; Guang Zhong Yang; Raad H Mohiaddin; Anitha Varghese; Clare Charrier; Jennifer Keegan; David N Firmin
Journal:  J Magn Reson Imaging       Date:  2003-05       Impact factor: 4.813

5.  Rapid extended coverage simultaneous multisection black-blood vessel wall MR imaging.

Authors:  Venkatesh Mani; Vitalii V Itskovich; Michael Szimtenings; Juan Gilberto S Aguinaldo; Daniel D Samber; Gabor Mizsei; Zahi A Fayad
Journal:  Radiology       Date:  2004-07       Impact factor: 11.105

6.  Enhanced image quality in black-blood MRI using the improved motion-sensitized driven-equilibrium (iMSDE) sequence.

Authors:  Jinnan Wang; Vasily L Yarnykh; Chun Yuan
Journal:  J Magn Reson Imaging       Date:  2010-05       Impact factor: 4.813

7.  Carotid arterial wall MRI at 3T using 3D variable-flip-angle turbo spin-echo (TSE) with flow-sensitive dephasing (FSD).

Authors:  Zhaoyang Fan; Zhuoli Zhang; Yiu-Cho Chung; Peter Weale; Sven Zuehlsdorff; James Carr; Debiao Li
Journal:  J Magn Reson Imaging       Date:  2010-03       Impact factor: 4.813

Review 8.  Clinical imaging of the high-risk or vulnerable atherosclerotic plaque.

Authors:  Z A Fayad; V Fuster
Journal:  Circ Res       Date:  2001-08-17       Impact factor: 17.367

9.  Three-dimensional T2-weighted MRI of the human femoral arterial vessel wall at 3.0 Tesla.

Authors:  Zhuoli Zhang; Zhaoyang Fan; Timothy J Carroll; YiuCho Chung; Peter Weale; Renate Jerecic; Debiao Li
Journal:  Invest Radiol       Date:  2009-09       Impact factor: 6.016

Review 10.  MRI of atherosclerosis.

Authors:  Chun Yuan; William S Kerwin
Journal:  J Magn Reson Imaging       Date:  2004-06       Impact factor: 4.813

View more
  58 in total

1.  Fast plaque burden assessment of the femoral artery using 3D black-blood MRI and automated segmentation.

Authors:  Bernard Chiu; Jie Sun; Xihai Zhao; Jinnan Wang; Niranjan Balu; Jiachang Chi; Jianrong Xu; Chun Yuan; William S Kerwin
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

2.  Three-dimensional acquisition of cerebral blood volume and flow responses during functional stimulation in a single scan.

Authors:  Ying Cheng; Peter C M van Zijl; James J Pekar; Jun Hua
Journal:  Neuroimage       Date:  2014-08-23       Impact factor: 6.556

3.  Rapid High-resolution, Self-registered, Dual Lumen-contrast MRI Method for Vessel-wall Assessment in Peripheral Artery Disease:: A Preliminary Investigation.

Authors:  Michael C Langham; Benoit Desjardins; Erin K Englund; Emile R Mohler; Thomas F Floyd; Felix W Wehrli
Journal:  Acad Radiol       Date:  2016-02-22       Impact factor: 3.173

4.  Black-blood native T1 mapping: Blood signal suppression for reduced partial voluming in the myocardium.

Authors:  Sebastian Weingärtner; Nadja M Meßner; Frank G Zöllner; Mehmet Akçakaya; Lothar R Schad
Journal:  Magn Reson Med       Date:  2016-09-16       Impact factor: 4.668

5.  Characterization of Craniocervical Artery Dissection by Simultaneous MR Noncontrast Angiography and Intraplaque Hemorrhage Imaging at 3T.

Authors:  Q Li; J Wang; H Chen; X Gong; N Ma; K Gao; L He; M Guan; Z Chen; R Li; D Mi; C Yuan; X Zhao; X H Zhao
Journal:  AJNR Am J Neuroradiol       Date:  2015-06-04       Impact factor: 3.825

Review 6.  MRI of carotid atherosclerosis.

Authors:  William S Kerwin; Thomas Hatsukami; Chun Yuan; Xue-Qiao Zhao
Journal:  AJR Am J Roentgenol       Date:  2013-03       Impact factor: 3.959

7.  Quantification of MRI signal of transgenic grafts overexpressing ferritin in murine myocardial infarcts.

Authors:  Anna V Naumova; Vasily L Yarnykh; Niranjan Balu; Hans Reinecke; Charles E Murry; Chun Yuan
Journal:  NMR Biomed       Date:  2012-02-24       Impact factor: 4.044

8.  Prediction of high-risk plaque development and plaque progression with the carotid atherosclerosis score.

Authors:  Dongxiang Xu; Daniel S Hippe; Hunter R Underhill; Minako Oikawa-Wakayama; Li Dong; Kiyofumi Yamada; Chun Yuan; Thomas S Hatsukami
Journal:  JACC Cardiovasc Imaging       Date:  2014-03-13

9.  Joint intracranial and carotid vessel wall imaging in 5 minutes using compressed sensing accelerated DANTE-SPACE.

Authors:  Sen Jia; Lei Zhang; Lijie Ren; Yulong Qi; Jinhao Ly; Na Zhang; Ye Li; Xin Liu; Hairong Zheng; Dong Liang; Yiu-Cho Chung
Journal:  Eur Radiol       Date:  2019-08-01       Impact factor: 5.315

Review 10.  Three-Dimensional Carotid Plaque MR Imaging.

Authors:  Chun Yuan; Dennis L Parker
Journal:  Neuroimaging Clin N Am       Date:  2015-10-19       Impact factor: 2.264

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.