Influence of formalin fixation on the biomechanical properties of human diaphyseal bone.

Klaus J Burkhart1, Tobias E Nowak, Jochen Blum, Sebastian Kuhn, Marcel Welker, Werner Sternstein, Lars P Mueller, Pol M Rommens.   

Abstract

Owing to the lack of fresh human bones, formalin-fixed specimens are frequently used in biomechanical testing. However, formalin fixation is assumed to affect the biomechanical properties of bone. The aim of this study was to compare axial and torsional stiffness and bone mineral density in fresh and embalmed human bones. The subtrochanteric regions of 12 pairs of fresh human femora were randomised into two groups for paired comparison. After bone mineral density measurement, one group was preserved in 4% formalin. After 6 weeks, bone mineral density was remeasured and each specimen underwent axial and torsional loading. The formalin group showed significant higher stiffness values for torsional and axial loads than the fresh group. Axial stiffness increased by 14.1%, whereas torsional stiffness increased by 14.3%. These differences were not reflected in bone mineral density values. Formalin fixation significantly influences the stiffness of human cadaveric bones. Fresh bones represent the in vivo conditions better than formalin fixed bones.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20939693     DOI: 10.1515/BMT.2010.043

Source DB:  PubMed          Journal:  Biomed Tech (Berl)        ISSN: 0013-5585            Impact factor:   1.411


  12 in total

1.  Mineralisation and mechanical strength of the glenoid cavity subchondral bone plate.

Authors:  Marko Kraljević; Valentin Zumstein; Dieter Wirz; Rolf Hügli; Magdalena Müller-Gerbl
Journal:  Int Orthop       Date:  2011-07-07       Impact factor: 3.075

2.  Accuracy of 3D fluoro-navigated anterior transpedicular screws in the subaxial cervical spine: an experimental study on human specimens.

Authors:  Jan Bredow; C Meyer; F Siedek; W F Neiss; L Löhrer; L P Müller; P Eysel; G Stein
Journal:  Eur Spine J       Date:  2017-07-27       Impact factor: 3.134

3.  The subtalar and talonavicular joints: a way to access the long-term load intake using conventional CT-data.

Authors:  Fabian Mueller; Sebastian Hoechel; Joerg Klaws; Dieter Wirz; Magdalena Müller-Gerbl
Journal:  Surg Radiol Anat       Date:  2013-09-20       Impact factor: 1.246

4.  Does formalin fixation influence MSCT/CBCT accuracy?

Authors:  Anna Seidel; Bastian Bergauer; Michael Lell; Thomas Buder; Cornelius von Wilmowsky; Eva Dach; Manfred Wichmann; Ragai-Edward Matta
Journal:  Surg Radiol Anat       Date:  2017-08-21       Impact factor: 1.246

5.  Elastic modulus of the femoral trochanteric region measured by scanning acoustic microscopy in elderly women.

Authors:  Hiroyuki Matsuki; Junichi Shibano; Michiaki Kobayashi; Yukio Nakatsuchi; Tetsuji Moriizumi; Hiroyuki Kato
Journal:  J Med Ultrason (2001)       Date:  2015-01-25       Impact factor: 1.314

6.  Embalmed and fresh frozen human bones in orthopedic cadaveric studies: which bone is authentic and feasible?

Authors:  Tobias Topp; Thorben Müller; Sebastian Huss; Peter Herbert Kann; Eberhard Weihe; Steffen Ruchholtz; Ralph Peter Zettl
Journal:  Acta Orthop       Date:  2012-09-14       Impact factor: 3.717

7.  Dose reduction potential in cone-beam CT imaging of upper extremity joints with a twin robotic x-ray system.

Authors:  Karsten Sebastian Luetkens; Süleyman Ergün; Henner Huflage; Andreas Steven Kunz; Carsten Herbert Gietzen; Nora Conrads; Lenhard Pennig; Lukas Goertz; Thorsten Alexander Bley; Tobias Gassenmaier; Jan-Peter Grunz
Journal:  Sci Rep       Date:  2021-10-11       Impact factor: 4.379

8.  Sequence of the Essex-Lopresti lesion--a high-speed video documentation and kinematic analysis.

Authors:  Kilian Wegmann; Karsten Engel; Klaus J Burkhart; Marc Ebinger; Robert Holz; Gert-Peter Brüggemann; Lars P Müller
Journal:  Acta Orthop       Date:  2014-01-30       Impact factor: 3.717

9.  Impact of Different Screw Designs on Durability of Fracture Fixation: In Vitro Study with Cyclic Loading of Scaphoid Bones.

Authors:  Dominik Gruszka; Robert Herr; Hans Hely; Peer Hofmann; Daniela Klitscher; Alexander Hofmann; Pol Maria Rommens
Journal:  PLoS One       Date:  2016-01-07       Impact factor: 3.240

10.  3D cone-beam CT with a twin robotic x-ray system in elbow imaging: comparison of image quality to high-resolution multidetector CT.

Authors:  Jan-Peter Grunz; Andreas Max Weng; Andreas Steven Kunz; Maike Veyhl-Wichmann; Rainer Schmitt; Carsten Herbert Gietzen; Lenhard Pennig; Stefan Herz; Süleyman Ergün; Thorsten Alexander Bley; Tobias Gassenmaier
Journal:  Eur Radiol Exp       Date:  2020-09-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.