The biomechanical analysis of relative position between implant and alveolar bone: finite element method.

Cheng-Chun Huang1, Ting-Hsun Lan, Huey-Er Lee, Chau-Hsiang Wang.   

Abstract

BACKGROUND: The purpose of this study is to analyze biomechanical interactions in the alveolar bone surrounding implants with smaller-diameter abutments by changing position of the fixture-abutment interface, loading direction, and thickness of cortical bone using the finite element method.
METHODS: Twenty different finite element models including four types of cortical bone thickness (0.5, 1, 1.5, and 2 mm) and five implant positions relative to bone crest (subcrestal 1, implant shoulder 1 mm below bone crest; subcrestal 0.5, implant shoulder 0.5 mm below bone crest; at crestal implant shoulder even with bone crest; supracrestal 0.5, implant shoulder 0.5 mm above bone crest; and supracrestal 1, implant shoulder 1 mm above bone crest) were analyzed. All models were simulated under two different loading angles (0 and 45 degrees) relative to the long axis of the implant, respectively. The three factors of implant position, loading type, and thickness of cortical bone were computed for all models.
RESULTS: The results revealed that loading type and implant position were the main factors affecting the stress distribution in bone. The stress values of implants in the supracrestal 1 position were higher than all other implant positions. Additionally, compared with models under axial load, the stress values of models under off-axis load increased significantly.
CONCLUSIONS: Both loading type and implant position were crucial for stress distribution in bone. The supracrestal 1 implant position may not be ideal to avoid overloading the alveolar bone surrounding implants.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20936917     DOI: 10.1902/jop.2010.100388

Source DB:  PubMed          Journal:  J Periodontol        ISSN: 0022-3492            Impact factor:   6.993


  3 in total

1.  Effect of proximal contact strength on the three-dimensional displacements of implant-supported cantilever fixed partial dentures under axial loading.

Authors:  Zhen-zhen Peng; Xin-min Chen; Jun Wang; Ai-jie Li; Zu-jie Xu
Journal:  J Zhejiang Univ Sci B       Date:  2013-06       Impact factor: 3.066

2.  Evaluation of the Effect of Buccolingual and Apicocoronal Positions of Dental Implants on Stress and Strain in Alveolar Bone by Finite Element Analysis.

Authors:  Farhood Massoumi; Mina Taheri; Abolghasem Mohammadi; Omid Amelirad
Journal:  J Dent (Tehran)       Date:  2018-01

3.  Finite Element Analysis and Biomechanical Testing to Analyze Fracture Displacement of Alveolar Ridge Splitting.

Authors:  Andres Stricker; Daniel Widmer; Boyko Gueorguiev; Dieter Wahl; Peter Varga; Fabian Duttenhoefer
Journal:  Biomed Res Int       Date:  2018-10-14       Impact factor: 3.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.