Literature DB >> 20934705

A new technique to measure micromotion distribution around a cementless femoral stem.

Michael Gortchacow1, Michael Wettstein, Dominique P Pioletti, Alexandre Terrier.   

Abstract

The interfacial micromotion is closely associated to the long-term success of cementless hip prostheses. Various techniques have been proposed to measure them, but only a few number of points over the stem surface can be measured simultaneously. In this paper, we propose a new technique based on micro-Computer Tomography (μCT) to measure locally the relative interfacial micromotions between the metallic stem and the surrounding femoral bone. Tantalum beads were stuck at the stem surface and spread at the endosteal surface. Relative micromotions between the stem and the endosteal bone surfaces were measured at different loading amplitudes. The estimated error was 10 μm and the maximal micromotion was 60 μm, in the loading direction, at 1400 N. This pilot study provided a local measurement of the micromotions in the 3 direction and at 8 locations on the stem surface simultaneously. This technique could be easily extended to higher loads and a much larger number of points, covering the entire stem surface and providing a quasi-continuous distribution of the 3D interfacial micromotions around the stem. The new measurement method would be very useful to compare the induced micromotions of different stem designs and to optimize the primary stability of cementless total hip arthroplasty.
Copyright © 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20934705     DOI: 10.1016/j.jbiomech.2010.09.023

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  4 in total

Review 1.  Biomechanical behaviours of the bone-implant interface: a review.

Authors:  Xing Gao; Manon Fraulob; Guillaume Haïat
Journal:  J R Soc Interface       Date:  2019-07-31       Impact factor: 4.118

2.  Effect of a collar on subsidence and local micromotion of cementless femoral stems: in vitro comparative study based on micro-computerised tomography.

Authors:  Valérie Malfroy Camine; Hannes A Rüdiger; Dominique P Pioletti; Alexandre Terrier
Journal:  Int Orthop       Date:  2017-06-07       Impact factor: 3.075

3.  Ex vivo loading of trussed implants for spine fusion induces heterogeneous strains consistent with homeostatic bone mechanobiology.

Authors:  Jason P Caffrey; Esther Cory; Van W Wong; Koichi Masuda; Albert C Chen; Jessee P Hunt; Timothy M Ganey; Robert L Sah
Journal:  J Biomech       Date:  2016-11-03       Impact factor: 2.712

4.  Mechanical micromodeling of stress-shielding at the bone-implant interphase under shear loading.

Authors:  Yoann Hériveaux; Sophie Le Cann; Manon Fraulob; Elsa Vennat; Vu-Hieu Nguyen; Guillaume Haïat
Journal:  Med Biol Eng Comput       Date:  2022-09-28       Impact factor: 3.079

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.