Literature DB >> 20921195

Lung volume does not alter the distribution of pulmonary perfusion in dependent lung in supine humans.

Susan R Hopkins1, Tatsuya J Arai, A Cortney Henderson, David L Levin, Richard B Buxton, G Kim Prisk.   

Abstract

There is a gravitational influence on pulmonary perfusion, including in the most dependent lung, where perfusion is reduced, termed Zone 4. Studies using xenon-133 show Zone 4 behaviour, present in the dependent 4 cm at total lung capacity (TLC), affects the dependent 11 cm at functional residual capacity (FRC) and almost all the lung at residual volume (RV). These differences were ascribed to increased resistance in extra-alveolar vessels at low lung volumes although other mechanisms have been proposed. To further evaluate the behaviour of perfusion in dependent lung using a technique that directly measures pulmonary perfusion and corrects for tissue distribution by measuring regional proton density, seven healthy subjects (age = 38 ± 6 years, FEV₁ = 104 ± 7% predicted) underwent magnetic resonance imaging in supine posture. Data were acquired in the right lung during breath-holds at RV, FRC and TLC. Arterial spin labelling quantified regional pulmonary perfusion, which was normalized for regional proton density measured using a fast low-angle shot technique. The height of the onset of Zone 4 behaviour was not different between lung volumes (P = 0.23). There were no significant differences in perfusion (expressed as ml min⁻¹ g⁻¹) between lung volumes in the gravitationally intermediate (RV = 8.9 ± 3.1, FRC = 8.1 ± 2.9, TLC = 7.4 ± 3.6; P = 0.26) and dependent lung (RV = 6.6 ± 2.4, FRC = 6.1 ± 2.1, TLC = 6.4 ± 2.6; P = 0.51). However, at TLC perfusion was significantly lower in non-dependent lung than at FRC or RV (3.6 ± 3.3, 7.7 ± 1.5, 7.9 ± 2.0, respectively; P < 0.001). These data suggest that the mechanism of the reduction in perfusion in dependent lung is unlikely to be a result of lung volume related increases in resistance in extra-alveolar vessels. In supine posture, the gravitational influence on perfusion is remarkably similar over most of the lung, irrespective of lung volume.

Entities:  

Mesh:

Year:  2010        PMID: 20921195      PMCID: PMC3010144          DOI: 10.1113/jphysiol.2010.196063

Source DB:  PubMed          Journal:  J Physiol        ISSN: 0022-3751            Impact factor:   5.182


  34 in total

1.  Perfusion imaging of the human lung using flow-sensitive alternating inversion recovery with an extra radiofrequency pulse (FAIRER).

Authors:  V M Mai; K D Hagspiel; J M Christopher; H M Do; T Altes; J Knight-Scott; A L Stith; T Maier; S S Berr
Journal:  Magn Reson Imaging       Date:  1999-04       Impact factor: 2.546

2.  MR perfusion imaging of pulmonary parenchyma using pulsed arterial spin labeling techniques: FAIRER and FAIR.

Authors:  V M Mai; S S Berr
Journal:  J Magn Reson Imaging       Date:  1999-03       Impact factor: 4.813

3.  EFFECT OF INTERSTITIAL PRESSURE OF THE LUNG ON PULMONARY CIRCULATION.

Authors:  S PERMUTT
Journal:  Med Thorac       Date:  1965

4.  Distribution of blood flow and ventilation-perfusion ratio in the lung, measured with radioactive carbon dioxide.

Authors:  J B WEST; C T DOLLERY
Journal:  J Appl Physiol       Date:  1960-05       Impact factor: 3.531

5.  Quantification of regional pulmonary blood flow using ASL-FAIRER.

Authors:  D S Bolar; D L Levin; S R Hopkins; L F Frank; T T Liu; E C Wong; R B Buxton
Journal:  Magn Reson Med       Date:  2006-06       Impact factor: 4.668

6.  Effects of age on pulmonary perfusion heterogeneity measured by magnetic resonance imaging.

Authors:  David L Levin; Richard B Buxton; James P Spiess; Tatsuya Arai; Jamal Balouch; Susan R Hopkins
Journal:  J Appl Physiol (1985)       Date:  2007-02-15

7.  Regional lung density and blood volume in nonsmoking and smoking subjects measured by PET.

Authors:  L H Brudin; C G Rhodes; S O Valind; P Wollmer; J M Hughes
Journal:  J Appl Physiol (1985)       Date:  1987-10

8.  Hypoxic pulmonary vasoconstriction does not contribute to pulmonary blood flow heterogeneity in normoxia in normal supine humans.

Authors:  T J Arai; A C Henderson; D J Dubowitz; D L Levin; P J Friedman; R B Buxton; G K Prisk; S R Hopkins
Journal:  J Appl Physiol (1985)       Date:  2008-12-04

9.  Pulmonary vascular tone is a determinant of basal lung perfusion in normal seated subjects.

Authors:  B Nemery; W Wijns; L Piret; F Caùwe; L Brasseur; A Frans
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1983-01

10.  Lung volumes in healthy nonsmoking adults.

Authors:  R O Crapo; A H Morris; P D Clayton; C R Nixon
Journal:  Bull Eur Physiopathol Respir       Date:  1982 May-Jun
View more
  11 in total

1.  Assessing potential errors of MRI-based measurements of pulmonary blood flow using a detailed network flow model.

Authors:  K S Burrowes; R B Buxton; G K Prisk
Journal:  J Appl Physiol (1985)       Date:  2012-04-26

Review 2.  Imaging lung perfusion.

Authors:  Susan R Hopkins; Mark O Wielpütz; Hans-Ulrich Kauczor
Journal:  J Appl Physiol (1985)       Date:  2012-05-17

3.  The effect of supine exercise on the distribution of regional pulmonary blood flow measured using proton MRI.

Authors:  E T Hall; R C Sá; S Holverda; T J Arai; D J Dubowitz; R J Theilmann; G K Prisk; S R Hopkins
Journal:  J Appl Physiol (1985)       Date:  2013-12-19

4.  The interdependent contributions of gravitational and structural features to perfusion distribution in a multiscale model of the pulmonary circulation.

Authors:  A R Clark; M H Tawhai; E A Hoffman; K S Burrowes
Journal:  J Appl Physiol (1985)       Date:  2011-02-03

5.  A statistical clustering approach to discriminating perfusion from conduit vessel signal contributions in a pulmonary ASL MR image.

Authors:  Shane C Walker; Amran K Asadi; Susan R Hopkins; Richard B Buxton; G K Prisk
Journal:  NMR Biomed       Date:  2015-07-16       Impact factor: 4.044

6.  Region of interest-based versus whole-lung segmentation-based approach for MR lung perfusion quantification in 2-year-old children after congenital diaphragmatic hernia repair.

Authors:  M Weis; V Sommer; F G Zöllner; C Hagelstein; K Zahn; T Schaible; S O Schoenberg; K W Neff
Journal:  Eur Radiol       Date:  2016-04-06       Impact factor: 5.315

7.  The effect of lung deformation on the spatial distribution of pulmonary blood flow.

Authors:  Tatsuya J Arai; Rebecca J Theilmann; Rui Carlos Sá; Michael T Villongco; Susan R Hopkins
Journal:  J Physiol       Date:  2016-07-08       Impact factor: 5.182

8.  Inhaled nitric oxide alters the distribution of blood flow in the healthy human lung, suggesting active hypoxic pulmonary vasoconstriction in normoxia.

Authors:  Amran K Asadi; Rui Carlos Sá; Nick H Kim; Rebecca J Theilmann; Susan R Hopkins; Richard B Buxton; G Kim Prisk
Journal:  J Appl Physiol (1985)       Date:  2014-11-26

9.  Rapid intravenous infusion of 20 mL/kg saline alters the distribution of perfusion in healthy supine humans.

Authors:  A C Henderson; R C Sá; I A Barash; S Holverda; R B Buxton; S R Hopkins; G K Prisk
Journal:  Respir Physiol Neurobiol       Date:  2011-12-31       Impact factor: 1.931

10.  High temporal versus high spatial resolution in MR quantitative pulmonary perfusion imaging of two-year old children after congenital diaphragmatic hernia repair.

Authors:  M Weidner; F G Zöllner; C Hagelstein; K Zahn; T Schaible; S O Schoenberg; L R Schad; K W Neff
Journal:  Eur Radiol       Date:  2014-07-20       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.