Literature DB >> 16680681

Quantification of regional pulmonary blood flow using ASL-FAIRER.

D S Bolar1, D L Levin, S R Hopkins, L F Frank, T T Liu, E C Wong, R B Buxton.   

Abstract

Pulsed arterial spin labeling (ASL) techniques have been theoretically and experimentally validated for cerebral blood flow (CBF) quantification. In this study ASL-FAIRER was used to measure regional pulmonary blood flow (rPBF) in seven healthy subjects. Two general ASL strategies were investigated: 1) a single-subtraction approach using one tag-control pair acquisition at an inversion time (TI) matched to the RR-interval, and 2) a multiple-subtraction approach using tag-control pairs acquired at various TIs. The mean rPBF averaged 1.70 +/- 0.38 ml/min/ml when measured with the multiple-subtraction approach, and was approximately 2% less when measured with the single-subtraction method (1.66 +/- 0.24 ml/min/ml). Assuming an average lung density of 0.33 g/ml, this translates into a regional perfusion of approximately 5.5 ml/g/min, which is comparable to other measures of pulmonary perfusion. As with other ASL applications, a key problem with quantitative interpretation of the results is the physical gap between the tagging region and imaged slice. Because of the high pulsatility of PBF, ASL acquisition and data analysis differ significantly between the lung and the brain. The advantages and drawbacks of the single- vs. multiple-subtraction approaches are considered within a theoretical framework tailored to PBF. Copyright 2006 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16680681     DOI: 10.1002/mrm.20891

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  41 in total

1.  Assessing potential errors of MRI-based measurements of pulmonary blood flow using a detailed network flow model.

Authors:  K S Burrowes; R B Buxton; G K Prisk
Journal:  J Appl Physiol (1985)       Date:  2012-04-26

Review 2.  Imaging lung perfusion.

Authors:  Susan R Hopkins; Mark O Wielpütz; Hans-Ulrich Kauczor
Journal:  J Appl Physiol (1985)       Date:  2012-05-17

3.  Development of functional chest imaging with a dynamic flat-panel detector (FPD).

Authors:  Rie Tanaka; Shigeru Sanada; Masaki Fujimura; Masahide Yasui; Kazuya Nakayama; Takeshi Matsui; Norio Hayashi; Osamu Matsui
Journal:  Radiol Phys Technol       Date:  2008-04-01

4.  Lung volume does not alter the distribution of pulmonary perfusion in dependent lung in supine humans.

Authors:  Susan R Hopkins; Tatsuya J Arai; A Cortney Henderson; David L Levin; Richard B Buxton; G Kim Prisk
Journal:  J Physiol       Date:  2010-10-04       Impact factor: 5.182

Review 5.  [MRI methods for pulmonary ventilation and perfusion imaging].

Authors:  G Sommer; G Bauman
Journal:  Radiologe       Date:  2016-02       Impact factor: 0.635

6.  Steep head-down tilt has persisting effects on the distribution of pulmonary blood flow.

Authors:  A Cortney Henderson; David L Levin; Susan R Hopkins; I Mark Olfert; Richard B Buxton; G Kim Prisk
Journal:  J Appl Physiol (1985)       Date:  2006-04-06

7.  Vertical gradients in regional lung density and perfusion in the supine human lung: the Slinky effect.

Authors:  Susan R Hopkins; A Cortney Henderson; David L Levin; Kei Yamada; Tatsuya Arai; Richard B Buxton; G Kim Prisk
Journal:  J Appl Physiol (1985)       Date:  2007-03-29

8.  Pulmonary perfusion in the prone and supine postures in the normal human lung.

Authors:  G Kim Prisk; Kei Yamada; A Cortney Henderson; Tatsuya J Arai; David L Levin; Richard B Buxton; Susan R Hopkins
Journal:  J Appl Physiol (1985)       Date:  2007-06-14

9.  The effect of supine exercise on the distribution of regional pulmonary blood flow measured using proton MRI.

Authors:  E T Hall; R C Sá; S Holverda; T J Arai; D J Dubowitz; R J Theilmann; G K Prisk; S R Hopkins
Journal:  J Appl Physiol (1985)       Date:  2013-12-19

10.  Estimation of perfusion properties with MR Fingerprinting Arterial Spin Labeling.

Authors:  Katherine L Wright; Yun Jiang; Dan Ma; Douglas C Noll; Mark A Griswold; Vikas Gulani; Luis Hernandez-Garcia
Journal:  Magn Reson Imaging       Date:  2018-03-12       Impact factor: 2.546

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.