Literature DB >> 2090800

Feasible cone beam scanning methods for exact reconstruction in three-dimensional tomography.

H Kudo1, T Saito.   

Abstract

Feasible cone beam scanning methods that permit exact reconstruction in three-dimensional tomography are proposed, and their performances are investigated using the theory developed by Kirillov [Sov. Math. Dokl. 2, 268 (1961)], Tuy [SIAM J. Appl. Math. 43, 546 (1983)], and Smith [IEEE Trans. Med. Imaging MI-4, 14 (1985)]. The proposed methods move an apex of a cone on two circles that are perpendicular to each other (orthogonal scan) or on a few twists of a helical curve (helical scan). The obtainable information, the feasibility of reconstruction, and the redundancy of measurement by some typical cone beam scanning methods are analyzed using the relationship between the cone beam projections and the three-dimensional Radon transform. Consequently it is found that the proposed methods can obtain the complete information about the three-dimensional Fourier transform of an object with less redundant measurement. Moreover, based on the analysis, a practically implementable reconstruction algorithm suitable for the proposed methods is derived. Experiments performed with both numerical and real x-ray projections demonstrate the validity of the proposed scanning methods and the reconstruction algorithm. Especially when a large cone angle is used, the proposed methods greatly improve the spatial resolution and the quantitative accuracy of reconstruction as compared with the method of circular apex motion.

Entities:  

Mesh:

Year:  1990        PMID: 2090800     DOI: 10.1364/josaa.7.002169

Source DB:  PubMed          Journal:  J Opt Soc Am A        ISSN: 0740-3232            Impact factor:   2.129


  3 in total

1.  Three-pinhole collimator to improve axial spatial resolution and sensitivity in pinhole SPECT.

Authors:  Christian Vanhove; Michel Defrise; Tony Lahoutte; Axel Bossuyt
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-11-14       Impact factor: 9.236

2.  Evaluation of tilted cone-beam CT orbits in the development of a dedicated hybrid mammotomograph.

Authors:  P Madhav; D J Crotty; R L McKinley; M P Tornai
Journal:  Phys Med Biol       Date:  2009-05-28       Impact factor: 3.609

3.  A new reconstruction strategy for image improvement in pinhole SPECT.

Authors:  Tsutomu Zeniya; Hiroshi Watabe; Toshiyuki Aoi; Kyeong Min Kim; Noboru Teramoto; Takuya Hayashi; Antti Sohlberg; Hiroyuki Kudo; Hidehiro Iida
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-03-17       Impact factor: 9.236

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.