Literature DB >> 2090413

The Gonioseton, a surgical treatment for chronic glaucoma.

G van der Veen1, W L Jongebloed, J G Worst.   

Abstract

A new and simple technique for glaucoma filtering surgery is presented. It is based on the introduction of a stainless steel microspiral or gonioseton into a goniopuncture by way of an ab interno procedure, minimising surgical trauma to the filtration area. Preliminary results are presented.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2090413     DOI: 10.1007/BF00164852

Source DB:  PubMed          Journal:  Doc Ophthalmol        ISSN: 0012-4486            Impact factor:   2.379


  8 in total

1.  Fibrosing response to aqueous. Its relation to glaucoma.

Authors:  E EPSTEIN
Journal:  Br J Ophthalmol       Date:  1959-11       Impact factor: 4.638

2.  Chemotactic activity of aqueous humor. A cause of failure of trabeculectomies?

Authors:  J P Joseph; I Grierson; R A Hitchings
Journal:  Arch Ophthalmol       Date:  1989-01

3.  Familial glaucoma. In nine generations of a South Hampshire family.

Authors:  J P Martin; E C Zorab
Journal:  Br J Ophthalmol       Date:  1974-05       Impact factor: 4.638

4.  New implant for drainage in glaucoma. Animal trial.

Authors:  A C Molteno
Journal:  Br J Ophthalmol       Date:  1969-03       Impact factor: 4.638

5.  Implants for draining neovascular glaucoma.

Authors:  A C Molteno; M M Van Rooyen; R S Bartholomew
Journal:  Br J Ophthalmol       Date:  1977-02       Impact factor: 4.638

6.  Trabeculectomy: a retrospective long-term follow-up of 444 cases.

Authors:  K B Mills
Journal:  Br J Ophthalmol       Date:  1981-11       Impact factor: 4.638

7.  Glaucoma filtering surgery with 5-fluorouracil.

Authors:  E J Rockwood; R K Parrish; D K Heuer; G L Skuta; E Hodapp; P F Palmberg; M G Gressel; W Feuer
Journal:  Ophthalmology       Date:  1987-09       Impact factor: 12.079

8.  Filtering valve implant surgery for eyes wtih neovascular glaucoma.

Authors:  T Krupin; P Kaufman; A Mandell; R Ritch; C Asseff; S M Podos; B Becker
Journal:  Am J Ophthalmol       Date:  1980-03       Impact factor: 5.258

  8 in total
  2 in total

1.  Long term effect on IOP of a stainless steel glaucoma drainage implant (Ex-PRESS) in combined surgery with phacoemulsification.

Authors:  C E Traverso; F De Feo; A Messas-Kaplan; P Denis; S Levartovsky; E Sellem; F Badalà; Z Zagorski; A Bron; S Gandolfi; M Belkin
Journal:  Br J Ophthalmol       Date:  2005-04       Impact factor: 4.638

Review 2.  Modern concepts in antiglaucomatous implant surgery.

Authors:  T S Dietlein; J Jordan; C Lueke; G K Krieglstein
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-08-06       Impact factor: 3.117

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.