Literature DB >> 20887020

Porohyperelastic finite element modeling of abdominal aortic aneurysms.

Avinash Ayyalasomayajula1, Jonathan P Vande Geest, Bruce R Simon.   

Abstract

Abdominal aortic aneurysm (AAA) is the gradual weakening and dilation of the infrarenal aorta. This disease is progressive, asymptomatic, and can eventually lead to rupture--a catastrophic event leading to massive internal bleeding and possibly death. The mechanical environment present in AAA is currently thought to be important in disease initiation, progression, and diagnosis. In this study, we utilize porohyperelastic (PHE) finite element models (FEMs) to investigate how such modeling can be used to better understand the local biomechanical environment in AAA. A 3D hypothetical AAA was constructed with a preferential anterior bulge assuming both the intraluminal thrombus (ILT) and the AAA wall act as porous materials. A parametric study was performed to investigate how physiologically meaningful variations in AAA wall and ILT hydraulic permeabilities affect luminal interstitial fluid velocities and wall stresses within an AAA. A corresponding hyperelastic (HE) simulation was also run in order to be able to compare stress values between PHE and HE simulations. The effect of AAA size on local interstitial fluid velocity was also investigated by simulating maximum diameters (5.5 cm, 4.5 cm, and 3.5 cm) at the baseline values of ILT and AAA wall permeability. Finally, a cyclic PHE simulation was utilized to study the variation in local fluid velocities as a result of a physiologic pulsatile blood pressure. While the ILT hydraulic permeability was found to have minimal affect on interstitial velocities, our simulations demonstrated a 28% increase and a 20% decrease in luminal interstitial fluid velocity as a result of a 1 standard deviation increase and decrease in AAA wall hydraulic permeability, respectively. Peak interstitial velocities in all simulations occurred on the luminal surface adjacent to the region of maximum diameter. These values increased with increasing AAA size. PHE simulations resulted in 19.4%, 40.1%, and 81.0% increases in peak maximum principal wall stresses in comparison to HE simulations for maximum diameters of 35 mm, 45 mm, and 55 mm, respectively. The pulsatile AAA PHE FEM demonstrated a complex interstitial fluid velocity field the direction of which alternated in to and out of the luminal layer of the ILT. The biomechanical environment within both the aneurysmal wall and the ILT is involved in AAA pathogenesis and rupture. Assuming these tissues to be porohyperelastic materials may provide additional insight into the complex solid and fluid forces acting on the cells responsible for aneurysmal remodeling and weakening.

Entities:  

Mesh:

Year:  2010        PMID: 20887020     DOI: 10.1115/1.4002370

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  14 in total

1.  Mass transport of low density lipoprotein in reconstructed hemodynamic environments of human carotid arteries: the role of volume and solute flux through the endothelium.

Authors:  Sungho Kim; Don P Giddens
Journal:  J Biomech Eng       Date:  2015-02-11       Impact factor: 2.097

2.  A finite element study on variations in mass transport in stented porcine coronary arteries based on location in the coronary arterial tree.

Authors:  Joseph T Keyes; Bruce R Simon; Jonathan P Vande Geest
Journal:  J Biomech Eng       Date:  2013-06       Impact factor: 2.097

3.  Deciphering mechanical regulation of chondrogenesis in fibrin-polyurethane composite scaffolds enriched with human mesenchymal stem cells: a dual computational and experimental approach.

Authors:  Houman Zahedmanesh; Martin Stoddart; Patrick Lezuo; Christoph Forkmann; Markus A Wimmmer; Mauro Alini; Hans Van Oosterwyck
Journal:  Tissue Eng Part A       Date:  2014-01-11       Impact factor: 3.845

Review 4.  Biomechanical Rupture Risk Assessment: A Consistent and Objective Decision-Making Tool for Abdominal Aortic Aneurysm Patients.

Authors:  T Christian Gasser
Journal:  Aorta (Stamford)       Date:  2016-04-01

5.  Location-dependent coronary artery diffusive and convective mass transport properties of a lipophilic drug surrogate measured using nonlinear microscopy.

Authors:  Joseph T Keyes; Bruce R Simon; Jonathan P Vande Geest
Journal:  Pharm Res       Date:  2012-12-07       Impact factor: 4.200

Review 6.  Biochemomechanics of intraluminal thrombus in abdominal aortic aneurysms.

Authors:  J S Wilson; L Virag; P Di Achille; I Karsaj; J D Humphrey
Journal:  J Biomech Eng       Date:  2013-02       Impact factor: 2.097

7.  Detection of Aortic Wall Inclusion Using Regional Pulse Wave Propagation and Velocity In Silico.

Authors:  Danial Shahmirzadi; Elisa E Konofagou
Journal:  Artery Res       Date:  2012-09       Impact factor: 0.597

8.  Deformationally dependent fluid transport properties of porcine coronary arteries based on location in the coronary vasculature.

Authors:  Joseph T Keyes; Danielle R Lockwood; Bruce R Simon; Jonathan P Vande Geest
Journal:  J Mech Behav Biomed Mater       Date:  2012-10-13

9.  Biomechanical rupture risk assessment of abdominal aortic aneurysms based on a novel probabilistic rupture risk index.

Authors:  Stanislav Polzer; T Christian Gasser
Journal:  J R Soc Interface       Date:  2015-12-06       Impact factor: 4.118

10.  Impact of poroelasticity of intraluminal thrombus on wall stress of abdominal aortic aneurysms.

Authors:  Stanislav Polzer; T Christian Gasser; Bernd Markert; Jiri Bursa; Pavel Skacel
Journal:  Biomed Eng Online       Date:  2012-08-29       Impact factor: 2.819

View more