Literature DB >> 20885280

C1 lateral mass screw insertion with protection of C1-C2 venous sinus: technical note and review of the literature.

Jie Pan1, Lijun Li, Lie Qian, Jun Tan, Guixin Sun, Xin Li.   

Abstract

STUDY
DESIGN: This is a technical note and review of the literature.
OBJECTIVE: We propose to describe a revised surgical technique of C1 lateral mass screw insertion with protection of C1-C2 venous sinus surrounding the C2 nerve root. SUMMARY OF BACKGROUND DATA: During C1 lateral mass screw insertion and in posterior C1-C2 fixation, iatrogenic injury of C1-C2 venous sinus results in bleeding, which is troublesome. Appropriate management of the venous sinus in this region is critical to successful surgery in this complex anatomic region.
METHODS: We reviewed 48 patients who underwent posterior C1-C2 fixation at our institution between September 2001 and October 2008. Twenty-four atlas screws were inserted by the originally described C1 lateral mass screw technique (group A), and 28 through a revised posterior arch and lateral mass screw technique (C1 transpedicular screw) (group B). The final group of 44 atlas screws was placed with our newly revised technique (group C).
RESULTS: Bleeding of venous sinus was encountered in 3 group A, 2 group B, and 1 group C atlas screw insertions. The incidence rate was 12.50% (A), 7.14% (B), and 2.27% (C). Statistical comparison showed no significant difference between the groups. All the cases were followed for a mean period of 28.1 month. Four patients in group A complained of postoperative numbness in occipitocervical region. No patients in group B or group C voiced this complaint. A high fusion rate was found in all 3 groups with no signs of implant failure.
CONCLUSION: Bleeding of C1-C2 venous sinus is vigorous and frustrating. The revised technique we describe provides theoretical and practical protection of venous sinus. In addition, the firm bony purchase of screws afforded by this technique contributes to achieving stabilization of the upper cervical spine and a high fusion rate.

Entities:  

Mesh:

Year:  2010        PMID: 20885280     DOI: 10.1097/BRS.0b013e3181e215ff

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  14 in total

1.  Prevalence and Morphologic Characteristics of Ponticulus Posticus: Analysis Using Cone-Beam Computed Tomography.

Authors:  Ahmet Ercan Sekerci; Emrah Soylu; Mehtap Payveren Arikan; Gozde Ozcan; Mehmet Amuk; Fatma Kocoglu
Journal:  J Chiropr Med       Date:  2015-11-05

2.  Placement of C1 Pedicle Screws Using Minimal Exposure: Radiographic, Clinical, and Literature Validation.

Authors:  Richard P Menger; Christopher M Storey; Menarvia K C Nixon; Justin Haydel; Anil Nanda; Anthony Sin
Journal:  Int J Spine Surg       Date:  2015-08-12

3.  The height for screw index (HSI) predicts the development of C2 nerve dysfunction associated with C1 lateral mass screw fixation for atlantoaxial instability.

Authors:  Da-Geng Huang; Ding-Jun Hao; Yong-Hong Jiang; Yue Cheng; Jun-Wei Pan; Yong-Qian Qiang; Bao-Rong He; Li-Xiong Qian
Journal:  Eur Spine J       Date:  2014-02-26       Impact factor: 3.134

4.  Suggestion of a safe zone for C1 pedicle screws depending on anatomical peculiarities.

Authors:  Maximilian Lenz; Arne Harland; Philipp Egenolf; Akanksha Perera; Lenhard Pennig; Jan Bredow; Peer Eysel; Max Joseph Scheyerer
Journal:  Eur Spine J       Date:  2021-09-24       Impact factor: 3.134

5.  Atlas (C1) lateral mass screw placement using the intersection between lateral mass and inferomedial edge of the posterior arch: a cadaveric study.

Authors:  Wongthawat Liawrungrueang; K Daniel Riew; Nantawit Sugandhavesa; Torphong Bunmaprasert
Journal:  Eur Spine J       Date:  2022-09-19       Impact factor: 2.721

6.  Atlantoaxial Stabilization Using C1 and C2 Laminar Screw Fixation.

Authors:  Takashi Tsuji; Kazuhiro Chiba; Yosuke Horiuchi; Tadahisa Urabe; Shota Fujita; Morio Matsumoto
Journal:  Asian Spine J       Date:  2017-04-12

7.  "Direct vision" operation of posterior atlantoaxial transpedicular screw fixation for unstable atlantoaxial fractures: A retrospective study.

Authors:  Liangliang Cao; Erzhu Yang; Jianguang Xu; Xiaofeng Lian; Bin Cai; Xiaokang Liu; Guowang Zhang
Journal:  Medicine (Baltimore)       Date:  2017-06       Impact factor: 1.889

8.  The Intersection Between Lateral Mass and Inferomedial Edge of the C1 Posterior Arch: A Reference Point for C1 Lateral Mass Screw Insertion.

Authors:  Torphong Bunmaprasert; Watcharapong Puangkaew; Nantawit Sugandhavesa; Wongthawat Liawrungrueang; K Daniel Riew
Journal:  Neurospine       Date:  2021-06-30

9.  Anatomic Consideration of the C1 Laminar Arch for Lateral Mass Screw Fixation via C1 Lateral Lamina : A Landmark between the Lateral and Posterior Lamina of the C1.

Authors:  Jung-Hwan Kim; Dai-Soon Kwak; Seung-Ho Han; Sung-Min Cho; Seung-Hoon You; Moon-Kyu Kim
Journal:  J Korean Neurosurg Soc       Date:  2013-07-31

10.  Unilateral lag-screw technique for an isolated anterior 1/4 atlas fracture.

Authors:  Semih Keskil; Murat Göksel; Ulaş Yüksel
Journal:  J Craniovertebr Junction Spine       Date:  2016 Jan-Mar
View more