Literature DB >> 20884971

The migration patterns of two versions of the Furlong cementless femoral stem: a randomised, controlled trial using radiostereometric analysis.

D J Simpson1, B J L Kendrick, M Hughes, S Glyn-Jones, H S Gill, G F Rushforth, D W Murray.   

Abstract

We have evaluated the difference in the migration patterns over two years of two cementless stems in a randomised, controlled trial using radiostereophotogrammetric analysis (RSA). The implants studied were the Furlong HAC stem, which has good long-term results and the Furlong Active stem, which is a modified version of the former designed to minimise stress concentrations between the implant and bone, and thus to improve fixation. A total of 23 Furlong HAC and 20 Furlong Active stems were implanted in 43 patients. RSA examinations were carried out immediately post-operatively and at six, 12 and 24 months post-operatively. The subsidence during the first year in the Furlong HAC stem, was approximately one-third that of the Furlong Active stem, the measured mean subsidence of the femoral head at six months being 0.27 mm (95% confidence interval (CI) 0.03 to 0.51) and 0.99 mm (95% CI 0.38 to 1.60), respectively (p = 0.03). One Active stem continued to subside during the second year. All hips, regardless of the type of stem were clinically successful as judged by the Oxford hip score and a derived pain score without any distinction between the two types of stem. The initial stability of the Furlong Active stem was not as good as the established stem which might compromise osseo-integration to the detriment of long-term success. The changes in the geometry of the stem, to minimise stress have affected the attainment of initial stability.

Entities:  

Mesh:

Year:  2010        PMID: 20884971     DOI: 10.1302/0301-620X.92B10.24399

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  12 in total

1.  High incidence of migration with poor initial fixation of the Accolade stem.

Authors:  Craig A White; Sasha Carsen; Kevin Rasuli; Robert J Feibel; Paul R Kim; Paul E Beaulé
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

2.  Early Migration Predicts Aseptic Loosening of Cementless Femoral Stems: A Long-term Study.

Authors:  Marcus R Streit; Daniel Haeussler; Thomas Bruckner; Tanja Proctor; Moritz M Innmann; Christian Merle; Tobias Gotterbarm; Stefan Weiss
Journal:  Clin Orthop Relat Res       Date:  2016-04-29       Impact factor: 4.176

3.  Radiographic Subsidence in Asymptomatic Patients After THR Using the Furlong Active HAP Stem.

Authors:  José Cordero-Ampuero; Pablo Peñalver; Rodrigo Antón; María Galán; Enrique Cordero
Journal:  HSS J       Date:  2013-06-21

Review 4.  Adherence of hip and knee arthroplasty studies to RSA standardization guidelines. A systematic review.

Authors:  Rami Madanat; Tatu J Mäkinen; Hannu T Aro; Charles Bragdon; Henrik Malchau
Journal:  Acta Orthop       Date:  2014-06-23       Impact factor: 3.717

Review 5.  What is the optimal time point to assess patient-reported recovery after hip and knee replacement? A systematic review and analysis of routinely reported outcome data from the English patient-reported outcome measures programme.

Authors:  John Patrick Browne; Hamad Bastaki; Jill Dawson
Journal:  Health Qual Life Outcomes       Date:  2013-07-30       Impact factor: 3.186

6.  Design modifications of the uncemented Furlong hip stem result in minor early subsidence but do not affect further stability: a randomized controlled RSA study with 5-year follow-up.

Authors:  Erik Weber; Martin Sundberg; Gunnar Flivik
Journal:  Acta Orthop       Date:  2014-09-01       Impact factor: 3.717

7.  Proximal femoral anatomy and collared stems in hip arthroplasty: is a single collar size sufficient?

Authors:  Nicolas Bonin; Jean-Emmanuel Gedouin; Vincent Pibarot; Jacques Bejui-Hughues; Hugo Bothorel; Mo Saffarini; Cécile Batailler
Journal:  J Exp Orthop       Date:  2017-10-03

8.  Prospective five-year subsidence analysis of a cementless fully hydroxyapatite-coated femoral hip arthroplasty component.

Authors:  Martin Clauss; Catherine Van Der Straeten; Marc Goossens
Journal:  Hip Int       Date:  2014-01-24       Impact factor: 2.135

9.  Biomechanical Evaluation of the Accuracy in Radiographic Assessment of Femoral Component Migration Measurement after Total Hip Arthroplasty.

Authors:  Mikayla Forness; Zachary J Podoll; Benjamin C Noonan; Alexander C M Chong
Journal:  Kans J Med       Date:  2020-04-17

Review 10.  Non-compliance with randomised allocation and missing outcome data in randomised controlled trials evaluating surgical interventions: a systematic review.

Authors:  Temitope E Adewuyi; Graeme MacLennan; Jonathan A Cook
Journal:  BMC Res Notes       Date:  2015-09-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.