Literature DB >> 20876272

Endocardial vagal atrioventricular node stimulation in humans: reproducibility on 18-month follow-up.

Pietro Rossi1, Stefano Bianchi, Sergio Valsecchi, Daniele Porcelli, Fabrizio Sgreccia, Antonio Lucifiero, Sergio Canonaco, Massimiliano Campoli, Mario Malavasi, Gianfranco Piccirillo, Raffaele Quaglione, Paolo Azzolini.   

Abstract

AIMS: Control of atrioventricular (AV) node conduction by means of high-frequency stimulation (HFS) of efferent AV node vagal stimulation (AVNS) fibres enables the ventricular rate (VR) to be modulated during atrial fibrillation (AF). The aims of this study were to verify, on 18-month follow-up, the reproducibility of the dromotropic effect obtained on implantation and the long-term reliability of the system in patients who received an implantable cardioverter-defibrillator (ICD) with a standard atrial lead positioned at a location suitable for AVNS. METHODS AND
RESULTS: We enrolled 12 patients with paroxysmal or persistent AF who were candidates for ICD. The right atrium was mapped to locate the pacing site, and a transvenous screw-in lead was implanted in that region. The voltages required for VR modulation (25% VR reduction) and complete AV block at different pulse durations (from 0.1 to 0.5 ms) were recorded. Eleven out of 12 patients underwent 18-month follow-up examination. Atrial pacing parameters were adequate and did not differ from the baseline values (all P > 0.05): pacing threshold 0.9 ± 0.5 V (0.5 ms pulse duration) and impedance 556 ± 121 Ω, with P-wave amplitude of 1.6 ± 0.7 mV. High-frequency stimulation induced VR modulation in nine patients and complete AV block in eight patients at pulse durations ≥0.3 ms. No differences were observed in the voltages for VR modulation and complete AV block between implantation and 18-month examination (all P > 0.100).
CONCLUSION: Ventricular rate control during AF was obtained under HFS 18 months after implantation in patients with the atrial lead positioned at a location suitable for AVNS. The pacing outputs needed to achieve the dromotropic effect were comparable to those measured on implantation.

Entities:  

Mesh:

Year:  2010        PMID: 20876272     DOI: 10.1093/europace/euq343

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  2 in total

1.  Myocardial repolarization dispersion and autonomic nerve activity in a canine experimental acute myocardial infarction model.

Authors:  Gianfranco Piccirillo; Federica Moscucci; Gaetana D'Alessandro; Matteo Pascucci; Pietro Rossi; Seongwook Han; Lan S Chen; Shien-Fong Lin; Peng-Sheng Chen; Damiano Magrì
Journal:  Heart Rhythm       Date:  2013-10-09       Impact factor: 6.343

2.  Stimulation of the intra-cardiac vagal nerves innervating the AV-node to control ventricular rate during AF: specificity, parameter optimization and chronic use up to 3 months.

Authors:  Lilian Kornet; Arne van Hunnik; Koen Michels; Sander Verheule; Alberto Della Scala; Teena West; Roger Kessels; Richard Cornelussen
Journal:  J Interv Card Electrophysiol       Date:  2011-10-04       Impact factor: 1.900

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.