Bonded multilayer ceramics and composites incorporating low-loss piezoceramics have been applied to arrays for ultrasound imaging to improve acoustic transmit power levels and to reduce internal heating. Commercially available hard PZT from multiple vendors has been characterized for microstructure, ability to be processed, and electroacoustic properties. Multilayers using the best materials demonstrate the tradeoffs compared with the softer PZT5-H typically used for imaging arrays. Three-layer PZT4 composites exhibit an effective dielectric constant that is three times that of single layer PZT5H, a 50% higher mechanical Q, a 30% lower acoustic impedance, and only a 10% lower coupling coefficient. Application of low-loss multilayers to linear phased and large curved arrays results in equivalent or better element performance. A 3-layer PZT4 composite array achieved the same transmit intensity at 40% lower transmit voltage and with a 35% lower face temperature increase than the PZT-5 control. Although B-mode images show similar quality, acoustic radiation force impulse (ARFI) images show increased displacement for a given drive voltage. An increased failure rate for the multilayers following extended operation indicates that further development of the bond process will be necessary. In conclusion, bonded multilayer ceramics and composites allow additional design freedom to optimize arrays and improve the overall performance for increased acoustic output while maintaining image quality.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20875996      PMCID: PMC2948242          DOI: 10.1109/TUFFC.2010.1655

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  18 in total

1.  On the feasibility of remote palpation using acoustic radiation force.

Authors:  K R Nightingale; M L Palmeri; R W Nightingale; G E Trahey
Journal:  J Acoust Soc Am       Date:  2001-07       Impact factor: 1.840

2.  Loss mechanisms in piezoelectrics: how to measure different losses separately.

Authors:  K Uchino; S Hirose
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2001-01       Impact factor: 2.725

3.  Observations of tissue response to acoustic radiation force: opportunities for imaging.

Authors:  Kathryn Nightingale; Rex Bentley; Gregg Trahey
Journal:  Ultrason Imaging       Date:  2002-07       Impact factor: 1.578

4.  On the thermal effects associated with radiation force imaging of soft tissue.

Authors:  Mark L Palmeri; Kathryn R Nightingale
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2004-05       Impact factor: 2.725

5.  Ultrasonic imaging using a 5-MHz multilayer/single-layer hybrid array for increased signal-to-noise ratio.

Authors:  C D Emery; S W Smith
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1999       Impact factor: 2.725

6.  Modeling 1-3 composite piezoelectrics: thickness-mode oscillations.

Authors:  W A Smith; B A Auld
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1991       Impact factor: 2.725

7.  Multilayer piezoelectric ceramics for two-dimensional array transducers.

Authors:  R L Goldberg; S W Smith
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1994       Impact factor: 2.725

8.  Multi-layered PZT/polymer composites to increase signal-to-noise ratio and resolution for medical ultrasound transducers.

Authors:  D M Mills; S W Smith
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1999       Impact factor: 2.725

9.  1.5-D high intensity focused ultrasound array for non-invasive prostate cancer surgery.

Authors:  L Curiel; F Chavrier; R Souchon; A Birer; J Y Chapelon
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2002-02       Impact factor: 2.725

10.  Characterization of hard piezoelectric lead-free ceramics.

Authors:  Shujun Zhang; Jong Bong Lim; Hyeong Jae Lee; Thomas R Shrout
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-08       Impact factor: 2.725

View more
  7 in total

1.  Acoustic radiation force-based elasticity imaging methods.

Authors:  Mark L Palmeri; Kathryn R Nightingale
Journal:  Interface Focus       Date:  2011-06-08       Impact factor: 3.906

2.  Characterization of piezoelectric ceramics and 1-3 composites for high power transducers.

Authors:  Hyeong Jae Lee; Shujun Zhang; Richard J Meyer; Nevin P Sherlock; Thomas R Shrout
Journal:  Appl Phys Lett       Date:  2012-07-18       Impact factor: 3.791

3.  Combined ultrasonic thermal ablation with interleaved ARFI image monitoring using a single diagnostic curvilinear array: a feasibility study.

Authors:  Kristin Frinkley Bing; Ned C Rouze; Mark L Palmeri; Veronica M Rotemberg; Kathryn R Nightingale
Journal:  Ultrason Imaging       Date:  2011-10       Impact factor: 1.578

4.  What challenges must be overcome before ultrasound elasticity imaging is ready for the clinic?

Authors:  Mark L Palmeri; Kathryn R Nightingale
Journal:  Imaging Med       Date:  2011-08

5.  Active Damping of Air-backed Ultrasonic Transducers Using Arbitrary Waveform Generators.

Authors:  Jesse Yen; Zoe Nussbaum
Journal:  Proc IEEE Ultrason Symp       Date:  2020-11-17

6.  Design of low-loss 1-3 piezoelectric composites for high-power transducer applications.

Authors:  Hyeong Jae Lee; Shujun Zhang
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2012-09       Impact factor: 2.725

7.  High temperature, high power piezoelectric composite transducers.

Authors:  Hyeong Jae Lee; Shujun Zhang; Yoseph Bar-Cohen; Stewart Sherrit
Journal:  Sensors (Basel)       Date:  2014-08-08       Impact factor: 3.576

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.