Literature DB >> 18263264

Multilayer piezoelectric ceramics for two-dimensional array transducers.

R L Goldberg1, S W Smith.   

Abstract

In medical ultrasound imaging, 2-D array transducers have become essential to implement dynamic focusing and phase-correction in the elevation dimension as well as real-time volumetric scanning. Unfortunately, the small size of a 2-D array element results in a small clamped capacitance and a large electrical impedance near resonance. These elements have poor sensitivity because their impedance is much higher than the electrical impedance of the transmit and receive circuitry. Sensitivity can be improved by using an N layer structure of PZT ceramic with the layers connected acoustically in series and electrically in parallel. For the multilayer ceramic (MLC), the damped capacitance is multiplied by a factor of N(2) and the electrical impedance by 1/N(2) compared to a single layer element of the same dimensions. A 3x43 phased-array transducer has been fabricated using 3 layer PZT-5H material. Each element had a thickness of 0.66 mm and an area of 0.37x3.5 mm. The MLC was manufactured using thick film technology with plated-through vias to electrically interconnect the electrode layers. The completed transducer was compared to a single layer control array of similar dimensions. With a light epoxy backing and a lambda/4 matching layer, the MLC array elements had an impedance of 100 Omega at series resonance of 2.25 MHz, compared to 800 Omega for the control elements. The lower impedance of the MLC elements resulted in a minimum round-trip insertion loss of 24.0 dB, compared to an 34.1 dB for the control array elements. These results were consistent with KLM modeling. B-scan images were made of cysts in a tissue-mimicking phantom and of the left kidney in vivo. The images clearly showed a higher signal-to-noise ratio for the MLC array compared to the control. As a result, 2-D arrays made of multilayer ceramics can be used to form images at a higher frequency and greater range than single layer arrays.

Year:  1994        PMID: 18263264     DOI: 10.1109/58.308512

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  7 in total

1.  New fabrication techniques for ring-array transducers for real-time 3D intravascular ultrasound.

Authors:  Edward D Light; Victor Lieu; Stephen W Smith
Journal:  Ultrason Imaging       Date:  2009-10       Impact factor: 1.578

2.  Imaging arrays with improved transmit power capability.

Authors:  Michael J Zipparo; Kristin F Bing; Kathryn R Nightingale
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2010-09       Impact factor: 2.725

3.  Multiple matching scheme for broadband 0.72Pb(Mg(13)Nb(23))O(3)-0.28PbTiO(3) single crystal phased-array transducer.

Authors:  S T Lau; H Li; K S Wong; Q F Zhou; D Zhou; Y C Li; H S Luo; K K Shung; J Y Dai
Journal:  J Appl Phys       Date:  2009-05-11       Impact factor: 2.546

4.  Piezoelectric films for high frequency ultrasonic transducers in biomedical applications.

Authors:  Qifa Zhou; Sienting Lau; Dawei Wu; K Kirk Shung
Journal:  Prog Mater Sci       Date:  2011-02

5.  A dual-layer transducer array for 3-D rectilinear imaging.

Authors:  Jesse T Yen; Chi Hyung Seo; Samer I Awad; Jong S Jeong
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-01       Impact factor: 2.725

6.  Short-lag spatial coherence imaging on matrix arrays, part II: Phantom and in vivo experiments.

Authors:  Marko Jakovljevic; Brett C Byram; Dongwoon Hyun; Jeremy J Dahl; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-07       Impact factor: 2.725

Review 7.  Review of cost reduction methods in photoacoustic computed tomography.

Authors:  Afreen Fatima; Karl Kratkiewicz; Rayyan Manwar; Mohsin Zafar; Ruiying Zhang; Bin Huang; Neda Dadashzadeh; Jun Xia; Kamran Mohammad Avanaki
Journal:  Photoacoustics       Date:  2019-07-26
  7 in total