Development of a clinically validated bulk failure test for ceramic crowns.

J Robert Kelly1, Patchnee Rungruanganunt, Ben Hunter, Francesca Vailati.   

Abstract

STATEMENT OF PROBLEM: Traditional testing of ceramic crowns creates a stress state and damage modes that differ greatly from those seen clinically. There is a need to develop and communicate an in vitro testing protocol that is clinically valid.
PURPOSE: The purpose of this study was to develop an in vitro failure test for ceramic single-unit prostheses that duplicates the failure mechanism and stress state observed in clinically failed prostheses. This article first compares characteristics of traditional load-to-failure tests of ceramic crowns with the growing body of evidence regarding failure origins and stress states at failure from the examination of clinically failed crowns, finite element analysis (FEA), and data from clinical studies. Based on this analysis, an experimental technique was systematically developed and test materials were identified to recreate key aspects of clinical failure in vitro.
MATERIAL AND METHODS: One potential dentin analog material (an epoxy filled with woven glass fibers; NEMA grade G10) was evaluated for elastic modulus in blunt contact and for bond strength to resin cement as compared to hydrated dentin. Two bases with different elastic moduli (nickel chrome and resin-based composite) were tested for influence on failure loads. The influence of water during storage and loading (both monotonic and cyclic) was examined. Loading piston materials (G10, aluminum, stainless steel) and piston designs were varied to eliminate Hertzian cracking and to improve performance. Testing was extended from a monolayer ceramic (leucite-filled glass) to a bilayer ceramic system (glass-infiltrated alumina). The influence of cyclic rate on mean failure loads was examined (2 Hz, 10 Hz, 20 Hz) with the extremes compared statistically (t test; α=.05).
RESULTS: Failure loads were highly influenced by base elastic modulus (t test; P<.001). Cyclic loading while in water significantly decreased mean failure loads (1-way ANOVA; P=.003) versus wet storage/dry cycling (350 N vs. 1270 N). G10 was not significantly different from hydrated dentin in terms of blunt contact elastic behavior or resin cement bond strength. Testing was successful with the bilayered ceramic, and the cycling rate altered mean failure loads only slightly (approximately 5%).
CONCLUSIONS: Test methods and materials were developed to validly simulate many aspects of clinical failure.
Copyright © 2010 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20875527     DOI: 10.1016/S0022-3913(10)60129-1

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  20 in total

Review 1.  Emerging ceramic-based materials for dentistry.

Authors:  I Denry; J R Kelly
Journal:  J Dent Res       Date:  2014-10-01       Impact factor: 6.116

Review 2.  Standardizing failure, success, and survival decisions in clinical studies of ceramic and metal-ceramic fixed dental prostheses.

Authors:  Kenneth J Anusavice
Journal:  Dent Mater       Date:  2012-01       Impact factor: 5.304

3.  The progressive wear and abrasiveness of novel graded glass/zirconia materials relative to their dental ceramic counterparts.

Authors:  Marina R Kaizer; Rafael R Moraes; Sergio S Cava; Yu Zhang
Journal:  Dent Mater       Date:  2019-03-01       Impact factor: 5.304

Review 4.  Evaluating dental zirconia.

Authors:  Yu Zhang; Brian R Lawn
Journal:  Dent Mater       Date:  2018-08-29       Impact factor: 5.304

5.  Effects of two grading techniques of zirconia material on the fatigue limit of full-contour 3-unit fixed dental prostheses.

Authors:  Regina Furbino Villefort; Marina Amaral; Gabriel Kalil Rocha Pereira; Tiago Moreira Bastos Campos; Yu Zhang; Marco Antonio Bottino; Luiz Felipe Valandro; Renata Marques de Melo
Journal:  Dent Mater       Date:  2017-01-21       Impact factor: 5.304

6.  Influence of piston material on the fatigue behavior of a glass-ceramic.

Authors:  Katia R Weber; Daniel E Meneghetti; Paula Benetti; Alvaro Della Bona; Jason A Griggs; Márcia Borba
Journal:  J Prosthet Dent       Date:  2021-09-02       Impact factor: 3.426

7.  Load-bearing properties of minimal-invasive monolithic lithium disilicate and zirconia occlusal onlays: finite element and theoretical analyses.

Authors:  Li Ma; Petra C Guess; Yu Zhang
Journal:  Dent Mater       Date:  2013-05-15       Impact factor: 5.304

8.  Fracture-resistant monolithic dental crowns.

Authors:  Yu Zhang; Zhisong Mai; Amir Barani; Mark Bush; Brian Lawn
Journal:  Dent Mater       Date:  2016-01-11       Impact factor: 5.304

9.  On edge chipping testing and some personal perspectives on the state of the art of mechanical testing.

Authors:  G D Quinn
Journal:  Dent Mater       Date:  2014-09-22       Impact factor: 5.304

10.  Edge chipping and flexural resistance of monolithic ceramics.

Authors:  Yu Zhang; James J-W Lee; Ramanathan Srikanth; Brian R Lawn
Journal:  Dent Mater       Date:  2013-10-17       Impact factor: 5.304

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.