Literature DB >> 20869832

Detection of low-affinity anti-drug antibodies and improved drug tolerance in immunogenicity testing by Octet(®) biolayer interferometry.

Jian Li1, Allen Schantz, Maureen Schwegler, Gopi Shankar.   

Abstract

We assessed the utility of the FortéBio Octet(®) system for detection of anti-drug antibodies (ADAs) against an investigational therapeutic human IgG1 monoclonal antibody (mAb), CNTO X. To understand the relative merits of this technology, key performance requirements were compared with two popularly accepted ADA detection methods, a step-wise bridging ELISA and a Meso Scale Discovery (MSD) homogeneous (single step binding) bridging ECLIA. When used to detect 13 monoclonal ADAs of varying affinities and one polyclonal ADA, all three methods demonstrated their greatest apparent sensitivity to the polyclonal sample (1, 6, and 130 ng/mL, respectively for ECLIA, ELISA, and Octet). Sensitivity to monoclonal ADAs tended to vary in accordance with their affinities, however, the sensitivity of the Octet method varied much less between ADAs. As a result, the above ranking became reversed such that Octet was the most and ELISA least sensitive for detection of low-affinity ADAs. With regard to drug tolerance, the presence of CNTO X could lead to false-negative assay results, although each method was affected to a different degree, with the Octet method tolerating up to 10 times more drug than the ECLIA method, which in turn tolerated up to 10 times more than the ELISA. Finally, the ECLIA and Octet methods were applied to the bioanalysis of cynomolgus monkey sera from a pre-clinical multiple dose study of CNTO X. Octet indicated 3 positive animals developed ADA as early as day 15 of the dosing phase while drug was present at nearly 1mg/mL. ECLIA detected only one of these, and only in a day 57 recovery sample after drug had cleared from circulation. We conclude that the Octet is a promising platform for detection of lower affinity ADAs and is particularly suitable for ADA detection when drug persists at levels that negatively impact bridging immunoassays.
Copyright © 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20869832     DOI: 10.1016/j.jpba.2010.08.022

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  21 in total

1.  Ligand binding assays in the 21st Century laboratory: platforms.

Authors:  Franklin P Spriggs; Zhandong Don Zhong; Afshin Safavi; Darshana Jani; Narasaiah Dontha; Anita Kant; Jenny Ly; Lia Brilando; Karolina Österlund; Nathalie Rouleau; Saloumeh Kadkhodayan Fischer; Martin Boissonneault; Chad Ray
Journal:  AAPS J       Date:  2012-03       Impact factor: 4.009

Review 2.  Evaluating and Reporting the Immunogenicity Impacts for Biological Products--a Clinical Pharmacology Perspective.

Authors:  Yow-Ming C Wang; Jie Wang; Yuen Yi Hon; Lin Zhou; Lanyan Fang; Hae Young Ahn
Journal:  AAPS J       Date:  2015-12-31       Impact factor: 4.009

Review 3.  From the bench to clinical practice: understanding the challenges and uncertainties in immunogenicity testing for biopharmaceuticals.

Authors:  G R Gunn; D C F Sealey; F Jamali; B Meibohm; S Ghosh; G Shankar
Journal:  Clin Exp Immunol       Date:  2016-01-19       Impact factor: 4.330

Review 4.  Theoretical considerations and practical approaches to address the effect of anti-drug antibody (ADA) on quantification of biotherapeutics in circulation.

Authors:  Marian Kelley; Ago B Ahene; Boris Gorovits; John Kamerud; Lindsay E King; Thomas McIntosh; Jihong Yang
Journal:  AAPS J       Date:  2013-03-30       Impact factor: 4.009

5.  Small-molecule inhibition of human immunodeficiency virus type 1 replication by targeting the interaction between Vif and ElonginC.

Authors:  Tao Zuo; Donglai Liu; Wei Lv; Xiaodan Wang; Jiawen Wang; Mingyu Lv; Wenlin Huang; Jiaxin Wu; Haihong Zhang; Hongwei Jin; Liangren Zhang; Wei Kong; Xianghui Yu
Journal:  J Virol       Date:  2012-02-29       Impact factor: 5.103

6.  Identification and affinity-quantification of ß-amyloid and α-synuclein polypeptides using on-line SAW-biosensor-mass spectrometry.

Authors:  Stefan Slamnoiu; Camelia Vlad; Mihaela Stumbaum; Adrian Moise; Kathrin Lindner; Nicole Engel; Mar Vilanova; Mireia Diaz; Christiaan Karreman; Marcel Leist; Thomas Ciossek; Bastian Hengerer; Marta Vilaseca; Michael Przybylski
Journal:  J Am Soc Mass Spectrom       Date:  2014-05-21       Impact factor: 3.109

7.  Assessment and reporting of the clinical immunogenicity of therapeutic proteins and peptides-harmonized terminology and tactical recommendations.

Authors:  G Shankar; S Arkin; L Cocea; V Devanarayan; S Kirshner; A Kromminga; V Quarmby; S Richards; C K Schneider; M Subramanyam; S Swanson; D Verthelyi; S Yim
Journal:  AAPS J       Date:  2014-04-24       Impact factor: 4.009

8.  Development and Utility of an ELISA Method for Sensitive and Specific Detection of IgE Antidrug Antibodies.

Authors:  Zhandong Don Zhong; Lynn L Jiang; Puneet Khandelwal; Adam W Clarke; Ray Bakhtiar; Linglong Zou
Journal:  AAPS J       Date:  2020-01-29       Impact factor: 4.009

9.  Patient-Specific Neutralizing Antibody Responses to Herpes Simplex Virus Are Attributed to Epitopes on gD, gB, or Both and Can Be Type Specific.

Authors:  Tina M Cairns; Zhen-Yu Huang; John R Gallagher; Yixin Lin; Huan Lou; J Charles Whitbeck; Anna Wald; Gary H Cohen; Roselyn J Eisenberg
Journal:  J Virol       Date:  2015-06-24       Impact factor: 5.103

10.  TACI deficiency enhances antibody avidity and clearance of an intestinal pathogen.

Authors:  Shoichiro Tsuji; Lucas Stein; Nobuhiko Kamada; Gabriel Nuñez; Richard Bram; Bruce A Vallance; Ana E Sousa; Jeffrey L Platt; Marilia Cascalho
Journal:  J Clin Invest       Date:  2014-10-01       Impact factor: 14.808

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.