Literature DB >> 20868456

Mandibular single-implant overdentures: preliminary results of a randomised-control trial on early loading with different implant diameters and attachment systems.

Nabeel H M Alsabeeha1, Alan G T Payne, Rohana K De Silva, W Murray Thomson.   

Abstract

OBJECTIVES: To determine surgical and prosthodontic outcomes of mandibular single-implant overdentures, opposing complete maxillary dentures, using a wide diameter implant and large ball attachment system compared with different regular diameter implants with standard attachment systems.
MATERIALS AND METHODS: Thirty-six edentulous participants (mean age 68 years, SD 9.2) were randomly assigned into three treatment groups (n=12). A single implant was placed in the mandibular midline of participants to support an overdenture using a 6-week loading protocol. The control group received Southern regular implants and standard ball attachments. One group received Southern 8-mm-wide implants and large ball attachments. Another group received Neoss regular implants and Locator attachments. Parametric and non-parametric tests of a statistical software package (SPSS) were used to determine between groups differences in marginal bone loss, implant stability, implant, and prosthodontic success (P<0.05).
RESULTS: Implant success after 1 year was 75% for Southern regular implant (control) group; and 100% for the Southern wide and Neoss regular implant groups (P=0.038). Mean marginal bone loss at 1 year was 0.19 mm (SD 0.39) without significant differences observed. Implant stability quotient (ISQ) at baseline was significantly lower for the Southern regular (control) group than the other two groups (P=0.001; P=0.009). At 1 year, no significant difference in implant stability was observed (mean ISQ 74.6, SD 6.1). The change in implant stability from baseline to 1 year was significant for the control group (P=0.025). Prosthodontic success was comparable between the groups but the maintenance (41 events overall, mean 1.2) was greater for the Locator and the standard ball attachments.
CONCLUSIONS: Mandibular single-implant overdentures are a successful treatment option for older edentulous adults with early loading protocol using implants of different diameters and with different attachment systems.
© 2010 John Wiley & Sons A/S.

Entities:  

Mesh:

Year:  2010        PMID: 20868456     DOI: 10.1111/j.1600-0501.2010.02004.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  19 in total

Review 1.  The single midline implant in the edentulous mandible: a systematic review.

Authors:  Nicole Passia; Matthias Kern
Journal:  Clin Oral Investig       Date:  2014-05-29       Impact factor: 3.573

2.  Two Years Retrospective Evaluation of Overdenture Retained by Symphyseal Single Implant Using Two Types of Attachments.

Authors:  Hussien Abdelfattah Ismail; Ahmed I Mahrous; Fahad H Banasr; Tarek A Soliman; Yasser Baraka
Journal:  J Int Oral Health       Date:  2015-06

3.  Effect of decreased implant healing time on bone (re)modeling adjacent to plateaued implants under functional loading in a dog model.

Authors:  Jing Dai; Ning Cheng; Richard J Miron; Bin Shi; Xiangrong Cheng; Yufeng Zhang
Journal:  Clin Oral Investig       Date:  2013-02-03       Impact factor: 3.573

4.  Pain and discomfort following immediate and delayed loading by overdentures in the single mandibular implant study (SMIS).

Authors:  T Mundt; N Passia; W Att; G Heydecke; S Freitag-Wolf; R G Luthardt; S Kappel; I K Konstantinidis; M Stiesch; S Wolfart; M Kern
Journal:  Clin Oral Investig       Date:  2016-08-12       Impact factor: 3.573

5.  Two versus three narrow-diameter implants with locator attachments supporting mandibular overdentures: a two-year prospective study.

Authors:  Ali M El-Sheikh; Omar F Shihabuddin; Sahar M F Ghoraba
Journal:  Int J Dent       Date:  2012-06-18

6.  A prospective study of early loaded single implant-retained mandibular overdentures: preliminary one-year results.

Authors:  Ali M El-Sheikh; Omar F Shihabuddin; Sahar M F Ghoraba
Journal:  Int J Dent       Date:  2012-03-15

Review 7.  WITHDRAWN: Interventions for replacing missing teeth: different types of dental implants.

Authors:  Marco Esposito; Yasmin Ardebili; Helen V Worthington
Journal:  Cochrane Database Syst Rev       Date:  2019-10-10

8.  Interventions for replacing missing teeth: attachment systems for implant overdentures in edentulous jaws.

Authors:  Alan Gt Payne; Nabeel Hm Alsabeeha; Momen A Atieh; Marco Esposito; Sunyoung Ma; Marwah Anas El-Wegoud
Journal:  Cochrane Database Syst Rev       Date:  2018-10-11

Review 9.  Implant and root supported overdentures - a literature review and some data on bone loss in edentulous jaws.

Authors:  Gunnar E Carlsson
Journal:  J Adv Prosthodont       Date:  2014-08-14       Impact factor: 1.904

10.  Single implant supported mandibular overdenture: A literature review.

Authors:  Sudhindra Mahoorkar; Srinidhi Bhat; Radhika Kant
Journal:  J Indian Prosthodont Soc       Date:  2016 Jan-Mar
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.