Literature DB >> 20865873

Continuous central venous oxygen saturation monitoring under varying physiological conditions in an animal model.

N Kissoon1, N Spenceley, G Krahn, R Milner.   

Abstract

We compared saturations from a paediatric central venous oximetry catheter with co-oximetry values with changes in drug infusions, intravascular blood volume and hypoxia in an animal model. Piglets (large white) were anaesthetised, intubated and mechanically ventilated. PediaSat oximetry catheters were placed in the superior vena cava via jugular vein cut-down and in the inferior vena cava percutaneously via the femoral vein. A carotid arterial catheter was placed via cut-down for blood sampling and pressure monitoring. Anaesthesia was maintained with continuous thiopentone and supplemental morphine. Haemodynamics (heart rate, mean arterial blood, central venous pressure), fibreoptic ScvO2 (ScvO2-inferior) from inferior vena cava, fibreoptic ScvO2 (ScvO2-superior) from superior vena cava and blood gas oximetry (ScvO2-co-ox) were measured simultaneously at predetermined intervals during increasing adrenaline and sodium nitroprusside infusions and during increasing hypoxia and hypovolaemia. There was good agreement of both superior vena cava and inferior vena cava ScvO2 catheters with co-oximetry during adrenaline and sodium nitroprusside infusions. During the hypoxia study there was good agreement between the co-oximeter to ScvO2-superior catheter but poor agreement with to the inferior vena cava catheter samples. In the hypovolaemic phase of the experiment there was good agreement between the measured co-oximetry value and ScvO2-superior catheter until the mean blood pressure reached 43 mmHg. The oximetry catheter is capable of identifying changes in ScvO2 under physiological conditions usually encountered in clinical medicine but was less accurate at the extremes of physiology and when placed in the inferior vena cava catheter especially during hypovolaemia and hypoxia.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20865873     DOI: 10.1177/0310057X1003800512

Source DB:  PubMed          Journal:  Anaesth Intensive Care        ISSN: 0310-057X            Impact factor:   1.669


  3 in total

1.  Inferior Vena Cava Oxygen Saturation during the First Three Postnatal Days in Preterm Newborns with and without Patent Ductus Arteriosus.

Authors:  Ece Yapakçı; Ayşe Ecevit; Deniz Anuk Ince; Mahmut Gökdemir; M Agah Tekindal; Hande Gülcan; Aylin Tarcan
Journal:  Balkan Med J       Date:  2014-09-01       Impact factor: 2.021

2.  Accuracy and precision of ScvO2 measured with the CeVOX-device: A prospective study in patients with a wide variation of ScvO2-values.

Authors:  Alexander Herner; Bernhard Haller; Ulrich Mayr; Sebastian Rasch; Lea Offman; Roland Schmid; Wolfgang Huber
Journal:  PLoS One       Date:  2018-04-17       Impact factor: 3.240

3.  Non-invasive capnodynamic mixed venous oxygen saturation during major changes in oxygen delivery.

Authors:  Anders Svedmyr; Mark Konrad; Mats Wallin; Magnus Hallbäck; Per-Arne Lönnqvist; Jacob Karlsson
Journal:  J Clin Monit Comput       Date:  2021-10-05       Impact factor: 1.977

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.