Literature DB >> 20864160

Notched fatigue behavior of PEEK.

Michacl C Sobieraj1, James E Murphy, Jennifer G Brinkman, Steve M Kurtz, Clare M Rimnac.   

Abstract

Poly(ether-ether-ketone) (PEEK) has been used as a load bearing orthopaedic implant material with clinical success. All of the orthopaedic applications contain stress concentrations (notches) in their design; however, little work has been done to examine the fatigue behavior of PEEK in the presence of a notch. This work examines both stress-life (S-N) fatigue behavior and the fracture behavior of unfilled PEEK under tension-tension loading in circumferentially grooved round bar specimens with different elastic stress concentration factors. It was found that the majority of the loading was elastic in nature, and that there was only a small portion on the lifetime where there was a detectable change in structural behavior prior to gross fracture. Fractographic analysis via SEM further elucidated the potential fracture micromechanisms. Additional analysis was conducted to estimate the percent of the lifetime spent in crack initiation vs. propagation, and it was found that the specimens spent the majority of the time in the crack initiation phase.
Copyright © 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20864160      PMCID: PMC3614075          DOI: 10.1016/j.biomaterials.2010.08.032

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  3 in total

1.  Flexible rods and the case for dynamic stabilization.

Authors:  Jason M Highsmith; Luis M Tumialán; Gerald E Rodts
Journal:  Neurosurg Focus       Date:  2007-01-15       Impact factor: 4.047

2.  Notch sensitivity of PEEK in monotonic tension.

Authors:  Michael C Sobieraj; Steven M Kurtz; Clare M Rimnac
Journal:  Biomaterials       Date:  2009-09-04       Impact factor: 12.479

Review 3.  PEEK biomaterials in trauma, orthopedic, and spinal implants.

Authors:  Steven M Kurtz; John N Devine
Journal:  Biomaterials       Date:  2007-08-07       Impact factor: 12.479

  3 in total
  5 in total

1.  Fracture Assessment of PEEK under Static Loading by Means of the Local Strain Energy Density.

Authors:  Mirco Peron; Seyed Mohammad Javad Razavi; Jan Torgersen; Filippo Berto
Journal:  Materials (Basel)       Date:  2017-12-13       Impact factor: 3.623

2.  Flexible growing rods: a biomechanical pilot study of polymer rod constructs in the stability of skeletally immature spines.

Authors:  Donita I Bylski-Austrow; David L Glos; Anne C Bonifas; Max F Carvalho; Matthew C Coombs; Peter F Sturm
Journal:  Scoliosis Spinal Disord       Date:  2016-09-23

3.  The mechanical response of a polyetheretherketone femoral knee implant under a deep squatting loading condition.

Authors:  Lennert de Ruiter; Dennis Janssen; Adam Briscoe; Nico Verdonschot
Journal:  Proc Inst Mech Eng H       Date:  2017-11-04       Impact factor: 1.617

4.  A Novel Approach for Assessing the Fatigue Behavior of PEEK in a Physiologically Relevant Environment.

Authors:  Mirco Peron; Jan Torgersen; Filippo Berto
Journal:  Materials (Basel)       Date:  2018-10-10       Impact factor: 3.623

5.  Thermo-Mechanical Behavior of Poly(ether ether ketone): Experiments and Modeling.

Authors:  A D Drozdov; J deClaville Christiansen
Journal:  Polymers (Basel)       Date:  2021-05-28       Impact factor: 4.329

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.