Literature DB >> 19733391

Notch sensitivity of PEEK in monotonic tension.

Michael C Sobieraj1, Steven M Kurtz, Clare M Rimnac.   

Abstract

Poly(ether-ether-ketone) (PEEK) has been used as a load bearing orthopaedic implant material with clinical success. All of the orthopaedic applications contain stress concentrations (notches) in their design; however, little work has been done to examine the stress-strain behavior of PEEK in the presence of a notch. This work examines both the stress-strain behavior and the fracture behavior of neat PEEK in a uniaxial loaded condition, and in circumferentially grooved round bar specimens with different elastic stress concentration factors. It was found that the material shows ductile necking in the smooth condition and that this is almost completely suppressed in the notched conditions. Additionally, the deformation and fracture micromechanisms changed drastically, from one of plastic deformation and void coalescence to one dominated by crazing and brittle fast fracture. This change in mechanism was explained via Neuber's theory of stresses at a notch.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19733391      PMCID: PMC2760343          DOI: 10.1016/j.biomaterials.2009.08.020

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  5 in total

1.  Iterative thresholding for segmentation of cells from noisy images.

Authors:  H S Wu; J Barba; J Gil
Journal:  J Microsc       Date:  2000-03       Impact factor: 1.758

2.  Notch strengthening and hardening behavior of conventional and highly crosslinked UHMWPE under applied tensile loading.

Authors:  M C Sobieraj; S M Kurtz; C M Rimnac
Journal:  Biomaterials       Date:  2005-06       Impact factor: 12.479

3.  On cavitation and macroscopic behaviour of amorphous polymer-rubber blends.

Authors:  Naima Belayachi; Noureddine Benseddiq; Moussa Naït-Abdelaziz; Adel Hamdi
Journal:  Sci Technol Adv Mater       Date:  2008-06-13       Impact factor: 8.090

4.  Tribological assessment of a flexible carbon-fibre-reinforced poly(ether-ether-ketone) acetabular cup articulating against an alumina femoral head.

Authors:  S C Scholes; I A Inman; A Unsworth; E Jones
Journal:  Proc Inst Mech Eng H       Date:  2008-04       Impact factor: 1.617

Review 5.  PEEK biomaterials in trauma, orthopedic, and spinal implants.

Authors:  Steven M Kurtz; John N Devine
Journal:  Biomaterials       Date:  2007-08-07       Impact factor: 12.479

  5 in total
  7 in total

1.  Do Surface Porosity and Pore Size Influence Mechanical Properties and Cellular Response to PEEK?

Authors:  F Brennan Torstrick; Nathan T Evans; Hazel Y Stevens; Ken Gall; Robert E Guldberg
Journal:  Clin Orthop Relat Res       Date:  2016-11       Impact factor: 4.176

2.  Notched fatigue behavior of PEEK.

Authors:  Michacl C Sobieraj; James E Murphy; Jennifer G Brinkman; Steve M Kurtz; Clare M Rimnac
Journal:  Biomaterials       Date:  2010-12       Impact factor: 12.479

Review 3.  Polyetheretherketone (PEEK) for medical applications.

Authors:  Ivan Vladislavov Panayotov; Valérie Orti; Frédéric Cuisinier; Jacques Yachouh
Journal:  J Mater Sci Mater Med       Date:  2016-06-03       Impact factor: 3.896

4.  Fracture Assessment of PEEK under Static Loading by Means of the Local Strain Energy Density.

Authors:  Mirco Peron; Seyed Mohammad Javad Razavi; Jan Torgersen; Filippo Berto
Journal:  Materials (Basel)       Date:  2017-12-13       Impact factor: 3.623

Review 5.  Preparation Methods for Improving PEEK's Bioactivity for Orthopedic and Dental Application: A Review.

Authors:  Davood Almasi; Nida Iqbal; Maliheh Sadeghi; Izman Sudin; Mohammed Rafiq Abdul Kadir; Tunku Kamarul
Journal:  Int J Biomater       Date:  2016-04-04

6.  Flexible growing rods: a biomechanical pilot study of polymer rod constructs in the stability of skeletally immature spines.

Authors:  Donita I Bylski-Austrow; David L Glos; Anne C Bonifas; Max F Carvalho; Matthew C Coombs; Peter F Sturm
Journal:  Scoliosis Spinal Disord       Date:  2016-09-23

7.  A Novel Approach for Assessing the Fatigue Behavior of PEEK in a Physiologically Relevant Environment.

Authors:  Mirco Peron; Jan Torgersen; Filippo Berto
Journal:  Materials (Basel)       Date:  2018-10-10       Impact factor: 3.623

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.