Literature DB >> 2086257

A clinical trial of aligning archwires.

K O'Brien1, D Lewis, W Shaw, E Combe.   

Abstract

The physical properties of a super-elastic archwire alloy (Titanol) and Nitinol were investigated by the means of a bending test. It was found that the alloy possessed super-elastic properties. A clinical trial was then carried out to compare the properties of two types of aligning archwire. Two groups of 20 patients with crowded dentitions were randomly allocated either Titanol or Nitinol, a conventional nickel-titanium alloy aligning archwire. High quality alginate impressions were taken after archwire placement in Edgewise fixed appliances and were repeated after a mean period of 35 days. The impressions were cast in dental stone and digitized using the Reflex Metrograph. The contact points of the teeth of the labial segments, together with four stable points in the rugae were recorded. This enabled the co-ordinates for the sequential study models to be superimposed upon one another, allowing tooth movement in three dimensions to be calculated. The measurement error expressed as error variance was 0.028 mm. The coefficient of reliability was 97 per cent. When tooth movement was analysed the mean movement per contact point for Titanol was 1.7 mm and for Nitinol 1.42 mm. This difference was not statistically significant (P less than 0.05, t-test). However, a clinical impression was that the super-elastic archwire proved superior to the Nitinol, because it was more readily engaged into grossly displaced teeth.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2086257     DOI: 10.1093/ejo/12.4.380

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  11 in total

1.  [The deactivation behavior and effectiveness of different orthodontic leveling arches--a dynamic analysis of the force systems].

Authors:  H A Schumacher; C Bourauel; D Drescher
Journal:  Fortschr Kieferorthop       Date:  1992-10

2.  [A new method for the quantitative and qualitative measurement of tooth movements].

Authors:  H Droschl; H P Bantleon; A P Muchitsch; F Weiland
Journal:  Fortschr Kieferorthop       Date:  1992-02

Review 3.  Which Orthodontic Wire and Working Sequence Should be Preferred for Alignment Phase? A Review.

Authors:  Sedef Sera Hepdarcan; R Burcu Nur Yılmaz; Didem Nalbantgil
Journal:  Turk J Orthod       Date:  2016-06-01

Review 4.  Orthodontic treatment for crowded teeth in children.

Authors:  Sarah Turner; Jayne E Harrison; Fyeza Nj Sharif; Darren Owens; Declan T Millett
Journal:  Cochrane Database Syst Rev       Date:  2021-12-31

5.  Pain and discomfort experienced after placement of a conventional or a superelastic NiTi aligning archwire. A randomized clinical trial.

Authors:  L M Fernandes; B Ogaard; L Skoglund
Journal:  J Orofac Orthop       Date:  1998       Impact factor: 1.938

6.  Alignment efficiency of superelastic coaxial nickel-titanium vs superelastic single-stranded nickel-titanium in relieving mandibular anterior crowding: a randomized controlled prospective study.

Authors:  Biju Sebastian
Journal:  Angle Orthod       Date:  2011-10-19       Impact factor: 2.079

7.  A clinical comparison of three aligning archwires in terms of alignment efficiency: A prospective clinical trial.

Authors:  Reem Sh Abdelrahman; Kazem S Al-Nimri; Emad F Al Maaitah
Journal:  Angle Orthod       Date:  2014-08-04       Impact factor: 2.079

8.  Alleviation of Lower Anterior Crowding with Super- Elastic and Heat-Activated NiTi Wires: A Prospective Clinical Trial.

Authors:  Pasupureddi Keerthana; Prasad Chitra
Journal:  Turk J Orthod       Date:  2021-06

Review 9.  Initial arch wires used in orthodontic treatment with fixed appliances.

Authors:  Yan Wang; Chang Liu; Fan Jian; Grant T McIntyre; Declan T Millett; Joy Hickman; Wenli Lai
Journal:  Cochrane Database Syst Rev       Date:  2018-07-31

10.  A comparative in-vivo evaluation of the alignment efficiency of 5 ligation methods: A prospective randomized clinical trial.

Authors:  Vijaya Bhaskara Reddy; Talapaneni Ashok Kumar; Mandava Prasad; Sivakumar Nuvvula; Rajedra Goud Patil; Praveen Kumar Reddy
Journal:  Eur J Dent       Date:  2014-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.