Literature DB >> 20862419

Immediate loading of unsplinted implants in the anterior mandible for overdentures: a case series.

Phillip Roe1, Joseph Y K Kan, Kitichai Rungcharassaeng, Jamie L Lozada, Alejandro S Kleinman, Charles J Goodacre, Jung-Wei Chen.   

Abstract

PURPOSE: This case series evaluated the implant success rate and peri-implant tissue response of immediately loaded unsplinted implants retaining a mandibular overdenture.
MATERIALS AND METHODS: Eight completely edentulous patients (five men, three women) with a mean age of 69.1 years were included in the study. All participants received new maxillary and mandibular complete dentures prior to implant placement. Two 4.0- 3 13-mm threaded implants with a fluoride-modified microrough titanium surface were placed mesial to the mandibular canine position bilaterally. Individual stud attachments were connected and torqued to 25 Ncm and the overdenture was immediately attached. The patients were evaluated clinically and radiographically at implant placement and at 3, 6, and 12 months after implant placement. The data were analyzed using the paired-samples t test and the Wilcoxon signed-ranks test at a significance level of a = .05.
RESULTS: At 12 months, all implants remained osseointegrated and showed an overall mean marginal bone change of -0.36 ± 0.29 mm and a mean Periotest value of -6.94 ± 0.73. The modified Plaque Index scores indicated improvements in oral hygiene over time. Surgical complications involved two episodes of implant rotational instability. Prosthetic complications were attributed to abutment loosening, the patients' inability to insert the prosthesis correctly, and soft tissue shrinkage.
CONCLUSIONS: The results of this study suggest that favorable implant success rates and peri-implant tissue responses can be achieved with mandibular overdentures retained with two immediately loaded unsplinted threaded implants with a fluoride-modified microrough titanium surface.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20862419

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  6 in total

1.  Rehabilitation of completely edentulous mandibular arch using immediately loaded transmucosal single-piece implants and overdenture.

Authors:  Dinesh Kumar; V S Legha; K V Arun Kumar; Shakeel Ahmad
Journal:  Med J Armed Forces India       Date:  2016-11-16

2.  A clinico radiographic study of immediate loading implants in rehabilitation of mandibular ridges.

Authors:  M Viswambaran; Vimal Arora; S H Gupta; R K Dhiman; N Thiruvalluvan
Journal:  Med J Armed Forces India       Date:  2014-08-22

3.  Comparative evaluation of bone in mandibular implant retained overdentures using delayed and immediate loading protocol: an in-vivo study.

Authors:  Manesh Lahori; A S Kaul; Sidhartha Chandra; Rahul Nagrath; Himanshu Gupta
Journal:  J Indian Prosthodont Soc       Date:  2012-12-27

4.  Marginal bone response of implants with platform switching and non-platform switching abutments in posterior healed sites: a 1-year prospective study.

Authors:  Yun-Chi Wang; Joseph Y K Kan; Kitichai Rungcharassaeng; Phillip Roe; Jaime L Lozada
Journal:  Clin Oral Implants Res       Date:  2014-01-03       Impact factor: 5.977

5.  Geriatric slim implants for complete denture wearers: clinical aspects and perspectives.

Authors:  Cedric Huard; Marion Bessadet; Emmanuel Nicolas; Jean-Luc Veyrune
Journal:  Clin Cosmet Investig Dent       Date:  2013-08-28

6.  Patient-reported outcomes with immediate-loaded two-implant-supported mandibular overdentures: Results of a 5-year prospective study.

Authors:  Yuriko Komagamine; Manabu Kanazawa; Daisuke Sato; Maiko Iwaki; Anna Miyayasu; Shunsuke Minakuchi
Journal:  J Dent Sci       Date:  2021-06-17       Impact factor: 2.080

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.