Literature DB >> 20858847

Pediatric 99mTc-MDP bone SPECT with ordered subset expectation maximization iterative reconstruction with isotropic 3D resolution recovery.

Eryn Caamano Stansfield1, Niall Sheehy, David Zurakowski, A Hans Vija, Frederic H Fahey, S Ted Treves.   

Abstract

PURPOSE: To perform a preliminary evaluation of the image quality of pediatric technetium 99m ((99m)Tc) methylene diphosphonate (MDP) bone single photon emission computed tomography (SPECT) by using iterative reconstruction-ordered subset expectation maximization with three-dimensional resolution recovery (OSEM-3D)-and to assess whether any improvements with use of this technique could lead to a reduction in patient dose or a shortening in imaging time.
MATERIALS AND METHODS: Institutional advisory board approval was obtained for this investigation. Fifty (99m)Tc-MDP SPECT studies of the spine were evaluated (36 female and 14 male patients; mean age, 15.5 years). Each study was acquired by using a dual-detector camera, with each detector rotating 360°. By using filtered back projection (FBP) and OSEM-3D, images were reconstructed from data generated by both detectors. Likewise, OSEM-3D was used to reconstruct data from a single detector simulating half the administered radiopharmaceutical activity. Two nuclear medicine physicians, blinded to the patient data, reviewed the images for image quality in four different categories by using a four-point scale: artifacts (category 1), lesions (category 2), noise (category 3), and image sharpness (category 4).
RESULTS: Compared with FBP, images reconstructed by using OSEM-3D with one or two detectors showed significant improvement in image quality with regard to lesion detection, noise level, and image sharpness (P < .02, .01, and .001, respectively). With OSEM-3D, no significant differences were observed when either one or two detectors were used.
CONCLUSION: Improved image quality of skeletal SPECT with either a 50% reduction in radiation dose or a 50% reduction in acquisition time or combination of the two can be achieved by using OSEM-3D. © RSNA, 2010.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20858847     DOI: 10.1148/radiol.10100102

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  8 in total

Review 1.  Dose Estimation in Pediatric Nuclear Medicine.

Authors:  Frederic H Fahey; Alison B Goodkind; Donika Plyku; Kitiwat Khamwan; Shannon E O'Reilly; Xinhua Cao; Eric C Frey; Ye Li; Wesley E Bolch; George Sgouros; S Ted Treves
Journal:  Semin Nucl Med       Date:  2016-11-09       Impact factor: 4.446

Review 2.  Evaluation of bone viability.

Authors:  Isabel Roca; Ignasi Barber; Cesar G Fontecha; Francisco Soldado
Journal:  Pediatr Radiol       Date:  2013-03-24

3.  Quantitative performance of advanced resolution recovery strategies on SPECT images: evaluation with use of digital phantom models.

Authors:  Hideo Onishi; Nobutoku Motomura; Koichi Fujino; Takahiro Natsume; Yasuhiro Haramoto
Journal:  Radiol Phys Technol       Date:  2012-07-13

4.  Three-minute SPECT/CT is sufficient for the assessment of bone metastasis as add-on to planar bone scintigraphy: prospective head-to-head comparison to 11-min SPECT/CT.

Authors:  Helle D Zacho; José A Biurrun Manresa; Ramune Aleksyniene; June A Ejlersen; Joan Fledelius; Henrik Bertelsen; Lars J Petersen
Journal:  EJNMMI Res       Date:  2017-01-05       Impact factor: 3.138

5.  Assessment of olfactory nerve by SPECT-MRI image with nasal thallium-201 administration in patients with olfactory impairments in comparison to healthy volunteers.

Authors:  Hideaki Shiga; Junichi Taki; Kohshin Washiyama; Junpei Yamamoto; Sakae Kinase; Koichi Okuda; Seigo Kinuya; Naoto Watanabe; Hisao Tonami; Kichiro Koshida; Ryohei Amano; Mitsuru Furukawa; Takaki Miwa
Journal:  PLoS One       Date:  2013-02-28       Impact factor: 3.240

6.  Development of a radiopharmaceutical dose calculator for pediatric patients undergoing diagnostic nuclear medicine studies.

Authors:  Anil Kumar Pandey; Sanjay Kumar Sharma; Punit Sharma; Priyanka Gupta; Rakesh Kumar
Journal:  Indian J Nucl Med       Date:  2013-04

7.  Optimization of 99m Tc whole-body SPECT/CT image quality: A phantom study.

Authors:  Mansour M Alqahtani; Kathy P Willowson; Chris Constable; Roger Fulton; Peter L Kench
Journal:  J Appl Clin Med Phys       Date:  2022-01-20       Impact factor: 2.102

8.  On the optimization of bone SPECT/CT in terms of image quality and radiation dose.

Authors:  Monika Tulik; Piotr Tulik; Teresa Kowalska
Journal:  J Appl Clin Med Phys       Date:  2020-10-27       Impact factor: 2.243

  8 in total