BACKGROUND AND STUDY AIMS: Nasogastric intubation , one of the most widely utilized therapeutic procedures in medical practice, is associated with trauma, pain, and discomfort, which can occur both at insertion and during the indwelling phase. Although lubricating jelly is useful during the insertion phase, insertion can still cause great discomfort. Furthermore, the jelly is rapidly absorbed and therefore is unable to decrease the friction between the tissues and the tube during the indwelling phase of the nasogastric tube. The aim of this study was to test a device, the NG-Shield, that generates surface acoustic waves on the surfaces of the nasogastric tube to reduce contact time and thus friction between the nasogastric tube and body tissues. PATIENT AND METHODS: Twenty-four healthy volunteers were enrolled in a single-center, crossover, blinded study, in which a nasogastric tube was inserted and left indwelling for 6 hours. Throughout the indwelling period the device was activated and deactivated alternately every hour, and the volunteers were questioned every hour about their pain and discomfort levels as well as grading pain and discomfort upon insertion and removal of the nasogastric tube. Pain and discomfort levels were compared between active and nonactive phases of the device. RESULTS: The activated NG-Shield was found to reduce both pain and discomfort significantly in both the nose and throat throughout the indwelling phase. CONCLUSIONS: The NG-Shield is a safe and effective device for reducing pain and discomfort associated with an indwelling nasogastric tube. © Georg Thieme Verlag KG Stuttgart · New York.
RCT Entities: Population
Interventions
Outcomes
BACKGROUND AND STUDY AIMS: Nasogastric intubation, one of the most widely utilized therapeutic procedures in medical practice, is associated with trauma , pain , and discomfort, which can occur both at insertion and during the indwelling phase. Although lubricating jelly is useful during the insertion phase, insertion can still cause great discomfort. Furthermore, the jelly is rapidly absorbed and therefore is unable to decrease the friction between the tissues and the tube during the indwelling phase of the nasogastric tube. The aim of this study was to test a device, the NG-Shield, that generates surface acoustic waves on the surfaces of the nasogastric tube to reduce contact time and thus friction between the nasogastric tube and body tissues. PATIENT AND METHODS: Twenty-four healthy volunteers were enrolled in a single-center, crossover, blinded study, in which a nasogastric tube was inserted and left indwelling for 6 hours. Throughout the indwelling period the device was activated and deactivated alternately every hour, and the volunteers were questioned every hour about their pain and discomfort levels as well as grading pain and discomfort upon insertion and removal of the nasogastric tube. Pain and discomfort levels were compared between active and nonactive phases of the device. RESULTS: The activated NG-Shield was found to reduce both pain and discomfort significantly in both the nose and throat throughout the indwelling phase. CONCLUSIONS: The NG-Shield is a safe and effective device for reducing pain and discomfort associated with an indwelling nasogastric tube. © Georg Thieme Verlag KG Stuttgart · New York.
Entities: Disease
Species
Mesh: See more »
Year: 2010
PMID: 20857371 DOI: 10.1055/s-0030-1255801
Source DB: PubMed Journal: Endoscopy ISSN: 0013-726X Impact factor: 10.093