Literature DB >> 20850674

The effect of cervical preflaring using different rotary nickel-titanium systems on the accuracy of apical file size determination.

Christian Tennert1, Josef Herbert, Markus Jörg Altenburger, Karl-Thomas Wrbas.   

Abstract

INTRODUCTION: An exact determination of the apical root canal diameter is crucial for correct cleaning and shaping of a root canal. The aim of this study was to investigate the discrepancies of the initial apical root canal diameter and the diameter that is measured by the initial apical file (IAF) after cervical flaring using current rotary nickel-titanium systems.
METHODS: Mesiobuccal canals of 40 extracted mandibular molars were randomly assigned to four groups. In the first group, root canals were not flared. Root canals of the other groups were preflared using FlexMaster (VDW, Munich, Germany), ProTaper (Dentsply, Konstanz, Germany), or RaCe (FKG Dentaire, Genf, Switzerland) instruments. The tooth length was determined by inserting an ISO 06 K-file to the apical foramen. The working length (WL) was set 1 mm short of the apical foramen. File sizes were increased after binding sensation was felt at the WL. Transversal sections of the WL regions were examined under stereomicroscope, and the diameter of the root canal and the IAF at WL were assessed.
RESULTS: Canals preflared with RaCe instruments had the lowest discrepancy between the apical root canal diameter and the IAF diameter (15.7 ± 9.7 μm) followed by ProTaper (22.2 ± 11.0 μm) and FlexMaster (35.0 ± 17.2 μm).
CONCLUSIONS: Preflaring of root canals prevents underestimation of the actual apical root canal diameter. The type of instruments used for preflaring show differences on the accuracy of IAF determination. Preflaring with larger tapered instruments leads to a more accurate apical sizing, and this information is crucial concerning the appropriate final diameter for complete apical shaping.
Copyright © 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20850674     DOI: 10.1016/j.joen.2010.06.017

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  5 in total

1.  Effect of pre-flaring and file size on the accuracy of two electronic apex locators.

Authors:  Manoel Brito-Júnior; Carla Cristina Camilo; Gil Moreira-Júnior; Jesus Djalma Pecora; Manoel Damião Sousa-Neto
Journal:  J Appl Oral Sci       Date:  2012 Sep-Oct       Impact factor: 2.698

2.  Influence of cervical preflaring using different rotary instruments on the accuracy of apical file size determination: A comparative in-vitro study.

Authors:  Shiv Aditya Sharma; Shashi Prabha Tyagi; Dakshita Joy Sinha; Udai Pratap Singh; Priyanka Chandra; Gagandeep Kaur
Journal:  J Conserv Dent       Date:  2014-11

3.  Evaluation of Torsional Resistance and Bending Stiffness of Coronal Flaring Nickel-Titanium Instruments.

Authors:  Theodoro Weissheimer; Murilo Alcalde; Julia Barrionuevo Cortez; Ricardo Rosa; Rodrigo Vivan; Pedro Henrique Souza Calefi; Marco Antonio Hungaro Duarte; Marcus Vinicius So
Journal:  Eur Endod J       Date:  2021-12

4.  To determine whether the first file to bind at the working length corresponds to the apical diameter in roots with apical curvatures both before and after preflaring.

Authors:  Jaidev Singh Dillon; Bobbin Gill
Journal:  J Conserv Dent       Date:  2012-10

5.  The Efficacy of FlexMaster's IntroFile, PreRaCe and Gates Glidden Drills in Straight-Line Access: A CBCT Assessment.

Authors:  Narges Farhad Mollashahi; Mahdi Sohrabi; Leila Farhad Mollashahi; Mojdeh Mehdizadeh
Journal:  Iran Endod J       Date:  2014-07-05
  5 in total