Literature DB >> 20850671

Effects of electropolishing surface treatment on the cyclic fatigue resistance of BioRace nickel-titanium rotary instruments.

Hélio P Lopes1, Carlos N Elias, Victor T L Vieira, Edson J L Moreira, Raquel V L Marques, Julio C Machado de Oliveira, Gilberto Debelian, José F Siqueira.   

Abstract

INTRODUCTION: This study evaluated the influence of electropolishing surface treatment on the number of cycles to fracture of BioRace rotary nickel-titanium endodontic instruments.
METHODS: BioRace size BR5C instruments with or without electropolishing surface treatment were used in an artificial curved canal under rotational speed of 300 rpm until fracture. Fractured surfaces and the helical shafts of fractured instruments were analyzed by scanning electron microscopy (SEM).
RESULTS: Polished instruments displayed a significantly higher number of cycles to fracture when compared with nonpolished instruments (P < .001). Actually, the number of cycles to fracture of a polished BR5C instrument was 124% higher than that of a nonpolished instrument. SEM analysis showed that the fractured surface of both polished and nonpolished BR5C instruments had ductile morphologic characteristics. Evaluation of the separated fragments after cyclic fatigue testing showed the presence of microcracks near the fracture surface. Polished instruments exhibited fine cracks that assumed an irregular path (zigzag crack pattern), whereas nonpolished instruments showed cracks running along the machining grooves.
CONCLUSIONS: Electropolishing surface treatment of BioRace endodontic instruments significantly increased the cyclic fatigue resistance.
Copyright © 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20850671     DOI: 10.1016/j.joen.2010.06.026

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  12 in total

1.  Detection of Procedural Errors with Stainless Steel and NiTi Instruments by Undergraduate Students Using Conventional Radiograph and Cone Beam Computed Tomography.

Authors:  Regis Augusto Aleixo Alves; João Batista Souza; Ana Helena Gonçalves Alencar; Jesus Djalma Pécora; Carlos Estrela
Journal:  Iran Endod J       Date:  2013-10-07

Review 2.  A Review of the Various Surface Treatments of NiTi Instruments.

Authors:  Zahed Mohammadi; Mohammad Karim Soltani; Sousan Shalavi; Saeed Asgary
Journal:  Iran Endod J       Date:  2014-10-07

3.  Cyclic Fatigue Resistance of WaveOne Gold, ProDesign R and ProDesign Logic Files in Curved Canals In Vitro.

Authors:  Sílvio Emanuel Acioly Conrado de Menezes; Shirley Machado Batista; Juliana Ouro Preto Lira; Gabriela Queiroz de Melo Monteiro
Journal:  Iran Endod J       Date:  2017

4.  Cyclic fatigue life of Tango-Endo, WaveOne GOLD, and Reciproc NiTi instruments.

Authors:  Koray Yılmaz; Taha Özyürek
Journal:  Restor Dent Endod       Date:  2017-04-11

5.  The Effect of Hydrofluoric Acid Surface Treatment on the Cyclic Fatigue Resistance of K3 NiTi Instruments.

Authors:  Kee-Yeon Kum; Seok Woo Chang
Journal:  Bioinorg Chem Appl       Date:  2017-05-02       Impact factor: 7.778

6.  Effect of ultrasound streaming on the disinfection of flattened root canals prepared by rotary and reciprocating systems.

Authors:  Layla Reginna Silva Munhoz de Vasconcelos; Raquel Zanin Midena; Paloma Gagliardi Minotti; Thais Cristina Pereira; Marco Antonio Hungaro Duarte; Flaviana Bombarda de Andrade
Journal:  J Appl Oral Sci       Date:  2017 Sep-Oct       Impact factor: 2.698

Review 7.  Rotary science and its impact on instrument separation: A focused review.

Authors:  Sandhya Anand Khasnis; Prem Prakash Kar; Apoorva Kamal; Jayaprakash D Patil
Journal:  J Conserv Dent       Date:  2018 Mar-Apr

Review 8.  Nickel-Titanium Rotary File Systems: What's New?

Authors:  Sadia Tabassum; Kamil Zafar; Fahad Umer
Journal:  Eur Endod J       Date:  2019-10-18

9.  Bending Resistance and Cyclic Fatigue Life of a new Single-File Reciprocating Instrument Waveone Gold.

Authors:  Emmanuel João Nogueira Leal Silva; Justine Monnerat Tinoco; Eduardo Muniz Barretto Tinoco; Victor Talarico Leal Vieira; Luciana Moura Sassone; Hélio Pereira Lopes
Journal:  Eur Endod J       Date:  2016-10-11

10.  Transportation Assessment in Simulated Curved Canals after preparation with Twisted File Adaptive and BT-Race instruments.

Authors:  Carlos-Vieira Andrade-Junior; Nilton-Dessaune Neto; Renata-Costa-Val Rodrigues; Henrique-Dos Santos Antunes; Mariana-Teixeira-Maneschy Porpino; Júlio-Cesar A Carvalhal; Luciana Armada
Journal:  J Clin Exp Dent       Date:  2017-09-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.