Literature DB >> 20843227

Application of gum elastic bougie to nasal intubation.

Hirofumi Arisaka1, Shigeki Sakuraba, Munetaka Furuya, Kazutoshi Higuchi, Hitoshi Yui, Shuya Kiyama, Kazu-Ichi Yoshida.   

Abstract

Gum elastic bougie (GEB), a useful device for difficult airway management, has seldom been used for nasotracheal intubation. Among 632 patients undergoing dental procedures or oral surgery, GEB was used successfully in 16 patients in whom conventional nasal intubation had failed because of anatomical problems or maldirection of the tip of the tracheal tube. We recommend that GEB should be applied from the first attempt for nasal intubation in patients with difficult airways.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20843227      PMCID: PMC3315278          DOI: 10.2344/0003-3006-57.3.112

Source DB:  PubMed          Journal:  Anesth Prog        ISSN: 0003-3006


  9 in total

1.  Survey of the use of the gum elastic bougie in clinical practice.

Authors:  I P Latto; M Stacey; J Mecklenburgh; R S Vaughan
Journal:  Anaesthesia       Date:  2002-04       Impact factor: 6.955

2.  An evaluation of the gum elastic bougie. Intubation times and incidence of sore throat.

Authors:  J P Nolan; M E Wilson
Journal:  Anaesthesia       Date:  1992-10       Impact factor: 6.955

3.  Successful difficult intubation. Tracheal tube placement over a gum-elastic bougie.

Authors:  S Dogra; R Falconer; I P Latto
Journal:  Anaesthesia       Date:  1990-09       Impact factor: 6.955

Review 4.  The Eschmann Tracheal Tube Introducer. (Gum elastic bougie).

Authors:  S Viswanathan; C Campbell; D G Wood; J M Riopelle; M Naraghi
Journal:  Anesthesiol Rev       Date:  1992 Nov-Dec

5.  Use of the endotracheal bougie introducer for difficult intubations.

Authors:  Michael P Phelan
Journal:  Am J Emerg Med       Date:  2004-10       Impact factor: 2.469

6.  Application of nasal flexible laryngeal mask airway in anesthesia for oral surgery.

Authors:  Hirofumi Arisaka; Masanao Matsumoto; Munetaka Furuya; Shigeki Sakuraba; Kazu-Ichi Yoshida
Journal:  J Anesth       Date:  2007-01-30       Impact factor: 2.078

7.  The use of a nasogastric tube as an aid in blind nasotracheal intubation: a postscript.

Authors:  N Sugiura; M Yamada; M Kainuma; T Miyake
Journal:  Anesthesiology       Date:  1997-08       Impact factor: 7.892

8.  Suction catheter-guided nasotracheal intubation.

Authors:  D S Lee; C I Yang
Journal:  Anesthesiology       Date:  1997-08       Impact factor: 7.892

9.  The use of stylet in blind nasotracheal intubation.

Authors:  F A Berry
Journal:  Anesthesiology       Date:  1984-10       Impact factor: 7.892

  9 in total
  7 in total

1.  Dual bougie technique for nasotracheal intubation.

Authors:  Rasjesh Mahajan; Parvaiz Ahmed; Firdose Shafi; Rishab Bassi
Journal:  Anesth Prog       Date:  2012

2.  Difficult Nasal Intubation Using Airway Scope® for a Child With Large Tumor.

Authors:  Tomoka Matsumura; Chihiro Suzuki; Kazumasa Kubota; Shunsuke Minakuchi; Haruhisa Fukayama
Journal:  Anesth Prog       Date:  2018

3.  Combined Use of a Gum Elastic Bougie and Video Laryngoscopy for Intubating a Patient With an Unexpected Laryngeal Papilloma.

Authors:  Nanako Ikeda; Tomoka Matsumura; Haruna Kono; Yukiko Baba; Miho Hanaoka; Haruhisa Fukayama
Journal:  Anesth Prog       Date:  2020-12-01

4.  Use of stylet in armored tube for nasotracheal intubation: Why not??

Authors:  Pooja Bihani; Pradeep Kumar Bhatia; Sadik Mohhammad; Priyanka Sethi
Journal:  Saudi J Anaesth       Date:  2017 Jul-Sep

5.  Intubation over a bougie: Nasal is not novel.

Authors:  Ron O Abrons; Randy W Loftus
Journal:  Saudi J Anaesth       Date:  2018 Apr-Jun

6.  Effect of Bougie-Guided Nasal Intubations upon Bleeding: A Randomised Controlled Trial.

Authors:  Prasanna Vadhanan; Debendra Kumar Tripaty
Journal:  Turk J Anaesthesiol Reanim       Date:  2017-11-27

7.  Incidence and predictors of difficult nasotracheal intubation with airway scope.

Authors:  Koyu Ono; Tomoko Goto; Daishi Nakai; Shuhei Ueki; Seiichiro Takenaka; Tomomi Moriya
Journal:  J Anesth       Date:  2014-01-17       Impact factor: 2.078

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.