Comparison of GlideScope video laryngoscope and intubating laryngeal mask airway with direct laryngoscopy for endotracheal intubation.

Orhan Cinar1, Erdem Cevik, Ali Osman Yildirim, Mehmet Yasar, Erden Kilic, Bilgin Comert.   

Abstract

The aim of this study was to determine whether GlideScope video laryngoscope (GVL) and intubating laryngeal mask airway (i-LMA) improve the intubation success rate and could be easily learned and performed by paramedic students when compared with the direct laryngoscopic (DL) method. The study was designed as a prospective randomized crossover trial that included 121 paramedic students. All participants were asked to intubate each Ambu Airway Management Trainer manikins after the lecture and demonstration. Successful intubation was defined as the passage of the tube through the vocal cord within 60 s. At the end of the study, a questionnaire survey was given to all participants about their preferences, and they were requested to define each method on an easy-difficult scale. Successful intubation was achieved by 95 students (78.5%) with DL, 112 students (92.6%) with i-LMA, and 111 students (91.7%) with GVL. Mean time of intubation was 25.06±14 s for DL, 22.32±12 s for i-LMA, and 22.63±10 s for GVL. Success rates of i-LMA and GVL were significantly higher compared with DL (P=0.005 and P=0.006, respectively). No significant difference was determined between i-LMA and GVL in terms of successful intubation (P>0.05). This study showed that GVL and i-LMA provided better intubation success rates and were easier for paramedic students when compared with the classic DL method.

Entities:  

Mesh:

Year:  2011        PMID: 20842041     DOI: 10.1097/MEJ.0b013e32833e79e6

Source DB:  PubMed          Journal:  Eur J Emerg Med        ISSN: 0969-9546            Impact factor:   2.799


  6 in total

1.  Assistant instructors facilitate simulation for medical students.

Authors:  Yinin Hu; Joanna Choi; Adela Mahmutovic; Helen Kim; Ivy A Le; Sara K Rasmussen
Journal:  J Surg Res       Date:  2014-11-29       Impact factor: 2.192

Review 2.  Mapping the use of simulation in prehospital care - a literature review.

Authors:  Anna Abelsson; Ingrid Rystedt; Björn-Ove Suserud; Lillemor Lindwall
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2014-03-28       Impact factor: 2.953

3.  Comparison of the airway access skills of prehospital staff in moving and stationary ambulance simulation: A randomized crossover study.

Authors:  Onur Karaca; Basak Bayram; Nese Colak Oray; Asli Acerer; Zeynep Sofuoglu
Journal:  Turk J Emerg Med       Date:  2017-03-23

4.  Learning and performance of endotracheal intubation by paramedical students: Comparison of GlideScope(®) and intubating laryngeal mask airway with direct laryngoscopy in manikins.

Authors:  Adil Omar Bahathiq; Tharwat Helmy Abdelmontaleb; Mohammed Khairt Newigy
Journal:  Indian J Anaesth       Date:  2016-05

5.  The novel intubating laryngeal tube (iLTS-D) is comparable to the intubating laryngeal mask (Fastrach) - a prospective randomised manikin study.

Authors:  Thomas Ott; Matthias Fischer; Tobias Limbach; Irene Schmidtmann; Tim Piepho; Ruediger R Noppens
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2015-06-08       Impact factor: 2.953

6.  Comparison of videolaryngoscopy and direct laryngoscopy by German paramedics during out-of-hospital cardiopulmonary resuscitation; an observational prospective study.

Authors:  Joachim Risse; Christian Volberg; Thomas Kratz; Birgit Plöger; Andreas Jerrentrup; Dirk Pabst; Clemens Kill
Journal:  BMC Emerg Med       Date:  2020-03-23
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.