Literature DB >> 20837893

Transcatheter aortic valve implantation: durability of clinical and hemodynamic outcomes beyond 3 years in a large patient cohort.

R Gurvitch1, D A Wood, E L Tay, J Leipsic, J Ye, S V Lichtenstein, C R Thompson, R G Carere, N Wijesinghe, F Nietlispach, R H Boone, S Lauck, A Cheung, J G Webb.   

Abstract

BACKGROUND: Although short- and medium-term outcomes after transcatheter aortic valve implantation are encouraging, long-term data on valve function and clinical outcomes are limited. METHODS AND
RESULTS: Consecutive high-risk patients who had been declined as surgical candidates because of comorbidities but who underwent successful transcatheter aortic valve implantation with a balloon-expandable valve between January 2005 and December 2006 and survived past 30 days were assessed. Clinical, echocardiographic, and computed tomographic follow-up examinations were performed. Seventy patients who underwent successful procedures and survived longer than 30 days were evaluated at a minimum follow-up of 3 years. At a median follow-up of 3.7 years (interquartile range 3.4 to 4.3 years), survival was 57%. Survival at 1, 2, and 3 years was 81%, 74%, and 61%, respectively. Freedom from reoperation was 98.5% (1 patient with endocarditis). During this early procedural experience, 11 patients died within 30 days, and 8 procedures were unsuccessful. When these patients were included, overall survival was 51%. Transaortic pressure gradients increased from 10.0 mm Hg (interquartile range 8.0 to 12.0 mm Hg) immediately after the procedure to 12.1 mm Hg (interquartile range 8.6 to 16.0 mm Hg) after 3 years (P=0.03). Bioprosthetic valve area decreased from a mean of 1.7±0.4 cm(2) after the procedure to 1.4±0.3 cm(2) after 3 years (P<0.01). Aortic incompetence after implantation was trivial or mild in 84% of cases and remained unchanged or improved over time. There were no cases of structural valvular deterioration, stent fracture, deformation, or valve migration.
CONCLUSIONS: Transcatheter aortic valve implantation demonstrates good medium- to long-term durability and preserved hemodynamic function, with no evidence of structural failure. The procedure appears to offer an adequate and lasting resolution of aortic stenosis in selected patients.

Entities:  

Mesh:

Year:  2010        PMID: 20837893     DOI: 10.1161/CIRCULATIONAHA.110.948877

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  36 in total

1.  Valvular disease: TAVI shown to be effective and durable.

Authors:  Bryony M Mearns
Journal:  Nat Rev Cardiol       Date:  2010-12       Impact factor: 32.419

2.  Comparison of multicenter registries and randomized control trials for transcatheter aortic valve replacement (TAVR).

Authors:  Shikhar Agarwal; E Murat Tuzcu; William Stewart; Navkaranbir Singh Bajaj; Lars G Svensson; Samir R Kapadia
Journal:  Indian Heart J       Date:  2013-07-10

Review 3.  Valve durability after transcatheter aortic valve implantation.

Authors:  Akash Kataruka; Catherine M Otto
Journal:  J Thorac Dis       Date:  2018-11       Impact factor: 2.895

4.  3-year outcomes of self-expanding Corevalve prosthesis - The Italian Registry.

Authors:  Marco Barbanti; Gian Paolo Ussia; Stefano Cannata; Alessandra Giarratana; Carmelo Sgroi; Corrado Tamburino
Journal:  Ann Cardiothorac Surg       Date:  2012-07

Review 5.  In vivo imaging and computational analysis of the aortic root. Application in clinical research and design of transcatheter aortic valve systems.

Authors:  Paul Schoenhagen; Alexander Hill; Tim Kelley; Zoran Popovic; Sandra S Halliburton
Journal:  J Cardiovasc Transl Res       Date:  2011-04-12       Impact factor: 4.132

6.  Transcatheter aortic valve implantation: Current status and future perspectives.

Authors:  Pablo Salinas; Raul Moreno; Jose L Lopez-Sendon
Journal:  World J Cardiol       Date:  2011-06-26

7.  In Vitro and Ex Vivo Hemodynamic Testing of an Innovative Occluder for Paravalvular Leak After Transcather Aortic Valve Implantation.

Authors:  Paolo Peruzzo; Gaetano Burriesci; Francesca Maria Susin; Andrea Colli
Journal:  J Cardiovasc Transl Res       Date:  2019-07-30       Impact factor: 4.132

Review 8.  Advanced 3-D analysis, client-server systems, and cloud computing-Integration of cardiovascular imaging data into clinical workflows of transcatheter aortic valve replacement.

Authors:  Paul Schoenhagen; Mathis Zimmermann; Juergen Falkner
Journal:  Cardiovasc Diagn Ther       Date:  2013-06

Review 9.  Computed tomography in the evaluation for transcatheter aortic valve implantation (TAVI).

Authors:  Paul Schoenhagen; Jörg Hausleiter; Stephan Achenbach; Milind Y Desai; E Murat Tuzcu
Journal:  Cardiovasc Diagn Ther       Date:  2011-12

Review 10.  Transcatheter aortic valve repair, imaging, and electronic imaging health record.

Authors:  Paul Schoenhagen; Juergen Falkner; David Piraino
Journal:  Curr Cardiol Rep       Date:  2013-01       Impact factor: 2.931

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.