Literature DB >> 20833569

Radiographic angles in hallux valgus: comparison between manual and computer-assisted measurements.

Subodh Srivastava1, Nachiappan Chockalingam, Tarek El Fakhri.   

Abstract

Radiographic angles are used to assess the severity of hallux valgus deformity, in preoperative planning, assessing postoperative outcomes, and in comparing results between interventions. The manual method to measure these angles has been shown to be prone to errors and to be time consuming. Computer programs are now available to assist in angular measurements. This study was undertaken to compare the reliability and time taken between the 2 methods. A total of 30 radiographs were used from a population of patients with hallux valgus deformity. The radiographs were digitized for computer-assisted measurements. The technical error of measurement (TEM) was calculated for intra- and interobserver data to assess the error in angular measurement with both methods. The technical error of measurement was lower with the computer-assisted method, suggesting that this method is more reliable. Furthermore, the time taken was also reduced with this method.
Copyright © 2010 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20833569     DOI: 10.1053/j.jfas.2010.07.012

Source DB:  PubMed          Journal:  J Foot Ankle Surg        ISSN: 1067-2516            Impact factor:   1.286


  4 in total

1.  Use of the iPhone for radiographic evaluation of hallux valgus.

Authors:  Tolga Ege; Ozkan Kose; Kenan Koca; Bahtiyar Demiralp; Mustafa Basbozkurt
Journal:  Skeletal Radiol       Date:  2012-06-06       Impact factor: 2.199

2.  Reliability and relationship of radiographic measurements in hallux valgus.

Authors:  Kyoung Min Lee; Soyeon Ahn; Chin Youb Chung; Ki Hyuk Sung; Moon Seok Park
Journal:  Clin Orthop Relat Res       Date:  2012-04-28       Impact factor: 4.176

3.  Point vs. traditional method evaluation of hallux valgus: interreader reliability and intermethod performance using X-ray and MRI.

Authors:  Nathan Heineman; Avneesh Chhabra; Lihua Zhang; Riham Dessouky; Dane Wukich
Journal:  Skeletal Radiol       Date:  2018-07-12       Impact factor: 2.199

4.  Reliability of different smartphones measuring the hallux valgus parameters in a new rapid method: a follow-up study.

Authors:  Lin Wang; Chao Zhang; Hao Liang; Jun Zhang; Weiyang Zhong; Zenghui Zhao; Tianji Huang; Xiaoji Luo
Journal:  BMC Musculoskelet Disord       Date:  2022-04-02       Impact factor: 2.362

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.