An electromagnetic reverse method of coil sensitivity mapping for parallel MRI - theoretical framework.

Jin Jin1, Feng Liu, Ewald Weber, Yu Li, Stuart Crozier.   

Abstract

In this paper, a novel sensitivity mapping method is proposed for the image domain parallel MRI (pMRI) technique. Instead of refining raw sensitivity maps by means of conventional image processing operations such as polynomial fitting, the presented method determines coil sensitivity profiles through an iterative optimization process. During the algorithm implementation the optimization cost function is defined as the difference between the raw sensitivity profile and the desired profile. The minimization is governed by the physics of low-frequency electromagnetic and reciprocity theories. The performance of the method was theoretically investigated and compared with that of a traditional polynomial fitting, against a range of system noise levels. It was found that, the new method produces high-fidelity sensitivity profiles with noise amplitudes, measured as root mean square deviation an order of magnitude less than that of the polynomial fitting method. Using the sensitivity profiles generated by our method, SENSE (sensitivity encoding) reconstructions produce significantly less image artefacts than conventional methods. The successful implementation of this method has far-reaching implications that accurate sensitivity mapping is not only important for parallel reconstruction, but also essential for its transmission analogy, such as Transmit SENSE. Crown
Copyright © 2010. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20833091     DOI: 10.1016/j.jmr.2010.08.009

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  3 in total

1.  Constrained Source Space MR Spectroscopy: Multiple Voxels, No Gradient Readout.

Authors:  K Landheer; A Sahgal; S Das; S J Graham
Journal:  AJNR Am J Neuroradiol       Date:  2015-06-18       Impact factor: 3.825

2.  Accelerated regularized estimation of MR coil sensitivities using augmented Lagrangian methods.

Authors:  Michael J Allison; Sathish Ramani; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2012-11-22       Impact factor: 10.048

3.  Regularized joint water-fat separation with B0 map estimation in image space for 2D-navigated interleaved EPI based diffusion MRI.

Authors:  Yiming Dong; Kirsten Koolstra; Malte Riedel; Matthias J P van Osch; Peter Börnert
Journal:  Magn Reson Med       Date:  2021-07-13       Impact factor: 4.668

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.